11054 Mill creek Rd. SE, Aumsville <br />94-00453 (52615) <br />February 15, 1994 <br />Page i <br /> <br />Marion County <br /> <br /> OREGON <br />COM, M U NI'i'¥ DEVELOPMENT <br />DEPARTMENT <br /> <br />Building Inspection - Dwelling Plan Review <br /> <br />The attached plans have been reviewed for compliance with the State of Oregon <br />1990 Edition One and Two Family Dwelling Specialty code. <br /> <br />This plan review covers the addition to and/or alteration of an existing <br />structure. This review is not intended to prohibit the building <br />inspector from requesting an evaluation of the acceptability of existing <br />structural members that may appear to be unsafe. Existing construction <br />not specifically detailed in the submitted plans and structural <br />calculations is beyond the scope of this review. <br /> <br />These plans are not approved as drawn. See the revisions required for <br />compliance with code requirements. <br /> <br />The plans submitted do not clearly show all the required framing details <br />(there is no information on foundation, floor or insulation shown). It <br />is the designer's responsibility to size all structural members and <br />fasteners for the appropriate loads and then show them on the plans. <br />(R-Iii.i) <br /> <br />A copy of approved plans shall be kept on the site of the building or <br />work at the time of inspection. (R-ii1.2) <br /> <br />Footings sections= 12 in. wide - 1 story; 15 in.- 2 story, 18 in. 3 <br />story. Footings shall extend not less than 12 in. below the finish <br />natural grade. (R-303) <br /> <br />Foundation walls shall extend at least 8 in. above the finished grade to <br />the foundation at all points. (R-304.2) (6 in. where pressure treated <br />sill plates are used.) <br /> <br />The foundation and its structural elements shall be capable of <br />accommodating all superimposed live, dead and other loads according to <br />Section R-201 and all lateral loads in accordance with the provisions of <br />the Code and accepted engineering design practice. (R-301.2) <br /> <br />A keyway in the footing is an acceptable method and will transfer the <br />lateral loads, provide a 18 inch long No. 3 dowels extending 12 inches <br />from the footing into the wall, 4 feet on center or the footing and <br />stemwall in one pour (monolithically). <br /> <br />Foundation plates shall be bolted to the foundation with minimum <br />1/2 inch diameter by 10 inch anchor bolts embedded at least 7 inches <br />into concrete or reinforced masonry and spaced not more than 6 feet <br />apart with a minimum of 2 bolts per piece with one bolt within 12 inches <br />of the end of each piece. Figure (R-303) <br /> <br />"APPROVED" only when this sheet is attached to plans <br /> <br /> <br />