My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permit - 1286231
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
94-XXXXX
>
Permit - 1286231
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/17/2011 10:40:15 AM
Creation date
9/3/2003 5:13:39 PM
Metadata
Fields
Template:
Permits
Permit Address
230-240 2ND ST
Permit City
Aumsville
Permit Number
94-00438
Permit Type
Permit
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Page 2 <br /> <br />Smoke detectors shall be installed outside of each separate sleeping <br />area in the immediate vicinity of the bedrooms and on each additional <br />story of the dwelling including basements. In dwelling units with split <br />levels, a smoke detector need be installed only on the upper level, <br />provided the lower level is less than one full story below the upper <br />level, except that if there is a door between levels then a detector is <br />required on each level. All detectors shall be interconnected such that <br />the actuation of one alarm will actuate all the alarms in the individual <br />unit and shall provide an alarm which will be audibl~ in all sleeping <br />areas. <br /> <br />10. <br /> <br />Wood framed walls a minimum of two feet and less than four feet wide at <br />garage door openings shall be provided with approved hold-down anchors <br />at each end of each wall segment. The hold-downs shal~ connect the wall <br />studding to the concrete foundation. An alternate design which is <br />designed to resist an 80 mile per hour wind load may be submitted to <br />Marion County for review with details shown on the plans and design <br />calculations showing compliance with this requirement. <br /> <br />Roof trusses are required to be designed by an Oregon registered <br />Engineer or Architect. For trusses manufactured by an approved <br />fabrication plant, have the design and layout drawings available at the <br />construction site for the framing inspection. All job site cutting er <br />modification of the roof trusses shall be clearly shown in the <br />engineer's design calculations and drawings. If trusses are to be built <br />at the job site, submit the engineer's design and construction plans to <br />the ~arion County Building Department prior to start of Construction and <br />have the approved drawings available at the site for the framing <br />inspection. <br /> <br />Approval as a result of this plan review or an inspection shall not be <br />construed to be an approval of a violation of the provisions of the dwelling <br />code or of other ordinances of the jurisdiction. Reviews or inspections <br />presuming to give authority to violate or cancel the provisions of the <br />dwelling code or of other ordinances of the Jurisdiction shall not be valid. <br /> <br />"APPROVED_" only when this sheet is attached to plans <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.