Laserfiche WebLink
Page 2 <br /> <br />10. <br /> <br />11. <br /> <br />Wood framed walls a minimum of two feet and less than four feet <br />wide at garage door openings shall be provided with approved hold- <br />down anchors at each end of each wall segment. The hold-downs <br />shall connect the wall studding to the concrete foundation. An <br />alternate design which is designed to resist an 80 mile per hour <br />wind load may be submitted to Marion County for review with <br />details shown on the plans and design calculations showing <br />compliance with this requirement. <br /> <br />Wood trusses shall be designed in accordance with approved <br />engineering practice. Trusses shall be braced according to their <br />appropriate engineered design. Truss members shall not be cut or <br />altered unless so designed. Have truss detials available on job <br />site for frame inspection. (R-702.9) <br /> <br />Use minimum ~2 4x8, or equivalent, header. <br /> <br />Approval as a result of this plan review or an inspection shall not be <br />construed to be an approval of a violation of the provisions of the dwelling <br />code or of other ordinances of the Jurisdiction. Reviews or inspections <br />presuming to give authority to violate or cancel the provisions of the <br />dwelling code or of other ordinances of the Jurisdiction shall not be valid. <br /> <br />tg <br /> <br />"APPROVED" only when this sheet is attached to plans <br /> <br /> <br />