Laserfiche WebLink
720 Delmar Dr., Anmsville <br />site #94-835 (53191) <br />March 30, 1994 <br />~age 1 <br /> <br />Marion County <br /> OREGON <br />COMMUNITY DLC'~/ELOPM~NT <br /> <br />~ilding Inspection - Dwelling Plan Review <br /> <br />The attached plans have been reviewed for compliance with the State of Oregon <br />1993 Edition One and Two Family Dwelling Specialty Code. <br /> <br />A copy of approved plans when required by the building official shall be <br />kept on the site of the building or work at the time of inspection. (R- <br />111.2) <br /> <br />Approved numbers or addresses shall be placed on all buildings in such a <br />position as to be plainly visible and legible from the street or road <br />frontin9 the property. (UFC 1O.20B) <br /> <br />The grade away ~rom foundation wails shall fall a minimum of 6 in. <br />within the first 10 ft., except as restricted by lot lines where the <br />fall will be a minimum of 6 in. regardless of the horizontal distance <br />available. (R-301.3) <br /> <br />Footings sections: 12 in. wide - 1 story; 15 in.- 2 story, 18 in. 3 <br />story. Footings shall extend not less than 12 in. below the finish <br />natural grade. (R-303) <br /> <br />Provide an access crawl hole to the uoderfloor space. The minimum size <br />opening required is 18 inches by 24 inches. (R-311.2) <br /> <br />~very sleeping room shall have at least one operable window approved for <br />emergency egress o~ rescue. The w£ndow sill height shall not be more <br />than 44 inches above the floor, The minimum net clear opening width <br />dimension shall be 20 inches. The minimum net opening height shall be <br />24 inches. The minimum net clear opening area shall be at least 5.7 <br />square feet. (R-210.2) <br /> <br />The garage shall be completely separated from the residence and its <br />attic area by means of 1/2-inch gypsum board or equivalent applied to <br />the garage side. The doer between the garage and residence shall be <br />equipped with solid wood doors not less than 1-3/8 inches in thickness <br />or 20-minute fire rated, or equ/ivalent. (R-209.2) <br /> <br />Heating and cooling appliances located in a garage shall be protected <br />from impact by automobiles. Appliances that generate a glow, spark of <br />flame capable of igniting gasoline vapors located in a garage shall be <br />installed with burners, burner ignition devices or heating elements and <br />switches at least 18 inches above the floor level. (M-1006.3) <br /> <br />In new construction, required smoke detectors shall receive their <br />primary powe~ from the building wiring and when primary power is <br />interrupted, shall receive power from a battery. <br /> <br />"APPROVED" only when this sheet is attached to plans <br /> <br /> <br />