My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permit - 1285667
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
94-XXXXX
>
Permit - 1285667
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/16/2011 1:46:07 PM
Creation date
9/3/2003 4:58:02 PM
Metadata
Fields
Template:
Permits
Permit Address
11373 MILL CREEK RD SE
Permit City
Aumsville
Permit Number
94-01217
Parcel Number
081W32A 01900
Permit Type
Permit
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
DIRECTOR <br />Craig O. Luedeman <br /> <br />BUiLDiNG INSPECTION <br />(503) 588-5147 <br /> <br />ENFORCEMENT <br />(503) 5~-5038 <br /> <br />BOARD OF <br />COMMISSIONERS <br />Randall Franke <br /> <br />OFFICER <br /> <br />Marion.Co ty.:. .. <br /> OREC]O:N '.' -. <br /> COMMUNITY DEVELOPMENT <br /> <br />DATE: <br /> <br />SUBJECT; <br /> <br />STRUCTURAL PLANS REVIEW <br /> <br />April 28~ 1994 <br /> <br />11373 Mill Creek Road <br /> <br />OWNER: <br /> <br />santiam Mobile Bomes <br /> <br />CONTROL NUMBER: <br />BUILDING PE~IT: <br /> <br />94-1217 <br />53516 <br /> <br />TYPE O~ CONSTRUCTION: 5-N <br /> <br />BUILDING CLASS: <br /> <br />The plans for the above indicated project are acceptable as submitted <br />subject to the following items noted belowt <br /> <br />The rise of every step in a stairway shall be not less than 4 inches nor <br />greater than 7 inches. The run shall be not less than 11 inches as <br />measured horizontally between the vertical planes of the furthermost <br />projection of adjacent treads. The largest tread run or riser height <br />within any flight of stairs shall not exceed the smallest by more than <br />3/8 inch. (3306(c)) <br /> <br />Stairways shall have handrails on each side. The hand grip portion of <br />handrails shall be not less than 1 1/2 inches nor more than 2 inches in <br />cross-sectional dimension or the shape shall provide an equivalent <br />gripping surface. Handrails shall be between 34 and 38 inches above the <br />nosing of treads. They shall be continuous the full length of the stairs. <br />Ends shall extend not less than 6 inches beyond the top and bottom risers <br />and be returned or terminate in newel posts or safety terminals. <br />(3306(i)) <br /> <br />Ail unenclosed floor and roof openings, open and glazed sides of <br />stairways, landings and ramps, balconies or porches which are more than 30 <br />inches above grade or floor below, and roofs used for other than service <br />of the building shall be protected by a guardrail. <br /> <br />Guardrails in areas accessible to the public shall be not less than <br />42-inche~ in height. The open space between the intermediate or <br />ornamental pattern of guardrails shall be such that a 4-inch diameter <br />sphere cannot pass through. (1712) <br /> <br />A sign shall be posted for each accessible parking space. The sign shall <br />be clearly visible to a person parking in the space and marked with the <br />international symbol of accessibility; indicate that the spaces are <br />reserved for persons with disabled person parking permits; and be designed <br />to standards adopted by the Oregon Transportation Commission. <br /> <br />Senator Building 220 High Street NE Salem, Oregon 97301-3670 <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.