Laserfiche WebLink
Page 2 <br /> <br />24 inches. The minimum net clear opening area shall be at least 5.7 <br />square feet. <br /> <br />10. <br /> <br />When alterations repairs or additions are made to an existing dwelling, <br />the entire buildiag shall be provided with smoke detectors located as <br />required for new dwellings. (R~215.1) <br /> <br />A readily accessible attic access shall be provided to any attic area <br />having a clear height of over 30 inches. A framed opening not less than <br />22 in. by 30 in. is required. (R-708) <br /> <br />12. <br /> <br />Purlin bracing may be used as a support when determining allowable <br />rafter spans. The angle between the purlin brace and a horizontal plane <br />shall be not less than 45 degrees. The lower end of the purlin brace <br />shall be supported by a load bearing wall, (R-701.1) <br /> <br />13. Provide support under ends of 5 1/8 x 15" glu lam beam in existing wall <br /> capable of carrying min. 5,500 lbs. each end. <br />Approval as a result of this plan review or an inspection shall not be <br />construed to be an approval of a violation of the provisions of the dwelling <br />code or of other ordinances of the Jurisdiction. Reviews or inspections <br />presuming to give authority to violate or cancel the provisions of the <br />dwelling code or of other ordinances of the jurisdiction shall not be valid. <br /> <br />"APPROVED" only when this sheet is attached to plans <br /> <br /> <br />