Laserfiche WebLink
Page 2 <br /> <br />10. <br /> <br />Porches, balconies or raised floor surfaces located more than 30 in. <br />above the floor or grade shall have guardrail not less than 36 inches in <br />height. Required guardrail shall have intermediate rails or ornamental <br />closures which will not allow passage of an object 6 in. or more in <br />diameter. Horizontal spacing between the vertical members in required <br />guardrails shall be a maximum of 4 inches at the nearest point between <br />the members. (R-214.2) <br /> <br />Every sleeping room shall have at least one operable window approved for <br />emergency egress or rescue. The window sill height shall not be more <br />than 44 inches above the floor. The minimum net clear opening width <br />dimension shall be 20 inches. The minimum net opening height shall be <br />24 inches. The minimum net clear opening area shall be at least 5.7 <br />square feet. (R-210.2) <br /> <br />The garage shall be completely separated from the residence and its <br />attic area by means of 1/2-inch gypsum board or equivalent applied to <br />the garage side. The door between the garage and residence shall be <br />equipped with solid wood doors not less than 1 3/8 inches in thickness <br />or 20-minute fire rated, or equivalent. (R-209.2) <br /> <br />Smoke detectors shall be installed outside of each separate sleeping <br />area in the immediate vicinity of the bedrooms and on each additional <br />story of the dwelling including basements. In dwelling units with split <br />levels, a smoke detector need be installed only on the upper level, <br />provided the lower level is less than one full story below the upper <br />level, except that if there is a door between levels then a detector is <br />required on each level. All detectors shall be interconnected such that <br />the actuation of one alarm will actuate all the alarms in the individual <br />unit and shall provide an alarm which will be audible in all sleeping <br />areas. (R-215.1) <br /> <br />12. <br /> <br />13. <br /> <br />primary power from the building wiring and when primary power is <br />interrupted, shall receive power from a battery. (R-215.2) <br /> <br />Water heaters having nonrigid water connections and over 4-feet i~ <br />height from the base to the top of the ta~k case shall be sschored or <br />strapped to the building to resist horizontal displacement due to <br />earthquake motion. (M-1006.2) <br /> <br />14. <br /> <br />Factory-built fireplace stoves, consisting of a freestanding fire <br />chamber assembly, that have been tested and are listed by a nationally <br />recognized testing laboratory, shall be installed in accordance with the <br />requirements of said listing and the manufacturer's instructions. <br />(R-905) <br /> <br />Approval as a result of this plan review or an inspection shall not be <br />construed to be an approval of a violation of the provisions of the dwelling <br />code or of other ordinances of the jurisdiction. Reviews or inspections <br />presuming to give authority to violate or Cancel the provisions of the <br />dwelling code or of other ordinances of the jurisdiction shall not be valid. <br /> <br />"APPROVED" only when this sheet is attached to plans <br /> <br /> <br />