Laserfiche WebLink
23924 Butteville Rd. NE, Aurora <br />January 4, 1993 <br />Page 2 <br /> <br />10. <br /> <br />11. <br /> <br />12. <br /> <br />13. <br /> <br />14. <br /> <br />Factory-built fireplace stoves, consisting of a freestanding fire <br />chamber assembly, that have been tested and ara listed by a nationally <br />recognized testing laboratory, shall be installed in accordance with the <br />requirements of said listing and the manufacturer's instructions. <br /> <br />Ail solid fuel-burning stoves which use wood as fuel shall be certified <br />by the Oregon Department of Environmental Quality or the federal <br />Environmental Protection Agency to meet cleaner-burning smoke emissions <br />standards pursuant to Oregon Revised Statute 468.655. <br /> <br />Each solid fuel burning masonry or factory built fireplace shall be <br />equipped with an outside air inlet. (R-906) <br /> <br />Energy Path #1 of the Oregon Residential Energy Code is as follows: <br />window class U~0.40; doors, other than main entry Ut0.20; main entry <br />door (maximum 24 squ. ft.) u=0.54; wall insulation R-21; underfloor <br />insulation R-25; flat ceilings R=38; vaulted ceilings R=30; skylight <br />class Ut0.50; basement walls R-21; slab floor edge insulation R-15; <br />forced air duct insulation R=8. <br /> <br />TJI floor joists are indicated on the plans as an optional floor system, <br />no size or TJI joist series is shown. Per conversation with Rufus <br />Kraxberger, provide 9 1/2" TJI/25 DF at 16" c.c. or submit an alternate <br />to Marion County Building Inspection for review. Install the TJI joists <br />per the manufacturer's installation instructions. <br /> <br />Provide a footing and framed wall at interior bearing wall between <br />master bedroom and great room per the TJI manufacturer's installation <br />instructions if TJI's are used. <br /> <br />Provide blocking per manufacturer's installation instructions at <br />concentrated point loads from girder trusses as some of these <br />loads/reactions are as high as 8,085 # and 11,014#. <br /> <br />Approval as a result of this plan review or an inspection shall not be <br />construed to be an approval of a violation of the provisions of the dwelling <br />code or of other ordinances of the jurisdiction. Reviews or inspections <br />presuming to give authority to violate or cancel the provisions of the <br />dwelling code or of other ordinances of the Jurisdiction shall not be valid. <br /> <br />SF <br /> <br />"APPROVED" only when this sheet is attached to plans <br /> <br /> <br />