Laserfiche WebLink
November 27, <br /> <br />APPLICANT: <br />SITE NUMBER: <br /> <br />CAPPING FILL SYSTEM CONSTRUCTION DETAIL SHEET <br /> <br />1992 <br /> <br /> HARRY THERRIEN <br /> 92-3624 <br /> <br /> Your site has been found suitable for a SAND FILTER PLUS CAPPING FILL <br />ALTERNATIVE SEWAGE DISPOSAL SYSTEM. The following construction specifications <br />shall apply to the installation of your septic system. <br /> <br /> 1. The septic tank shall have a minimum liquid capacity of 1000 <br /> gallons. <br /> <br />The projected daily sewage flow for this project is calculated at <br />450 ~allons Der day. Eased on soil conditions observed on this <br />site, the disposal field will be sized at 45 lineal feet oer 150 <br />qallons of projected daily sewage flow. A minimum Of 135 lineal <br />feet of disposal field will be required for your proposed develop- <br />ment. The disposal trenches are constructed two {2) feet wide and <br />on minimum ten (10) foot centers and with no line exceeding 125 <br />feet in length. The trenches and perforated pipe are installed <br />level (±1") and contoured to follow the natural ground surface. <br /> <br />The disposal field shall be constructed with ~al distribution <br />with a minimum trench depth of 12 inches and a maximum trench <br />depth of 12 inches. The capping fill material must be inspected <br />and approved prior to placement. The fill shall be of the same <br />textural class, or one class finer, than the native topsoil. The <br />disposal field area must be scarified to destroy any vegetative <br />mat on the surface. Fill material shall be evenly graded to a <br />final depth of sixteen (16) inches over the gravel. ~appinq Fill <br />~stems shall be constructed between June 1 and October 1 or <br />durinq such times when our staff finds sell moisture conditions <br /> <br />acceptable. <br /> <br /> 4. The site must be protected from traffic, livestock, farming or <br /> other damaging activities. <br /> <br /> An effluent lift pump may be necessary to construct the disposal field <br />in the approved area and at the correct depth. <br /> <br /> This approval is site specific to the area tested and the septic system <br />must be located in the immediate area of the test pits unless otherwise autho- <br />rized by this office. A new site evaluation may be required if the system is <br />proposed for a different area on the property. <br /> <br />SPECIAL CONDITIONS= <br /> This capping fill is an integral part of the sand filter system. <br /> Construct the drainfields within the immediate area of the westerly test <br /> pit. Observe all normal setback/separation distances. <br /> <br />THIS IS NOT A PERMIT TO INSTALL TBE SEPTIC SY~. DO NOT INSTALL ~HE SYSTEM <br /> <br />UNTIL A VALID PERMIT HAS BERM ISSUED BY THIS OFFICR. <br /> <br /> <br />