Laserfiche WebLink
Marion County <br /> <br /> OREGON <br />COMMUNITY DEVELOPMENT <br /> DEPARTMENT <br /> <br />B~P, ECTOR <br />Craig O, Luedeman <br /> <br />BUILDING INSPECTION <br /> <br />DATE: <br /> <br />SUBJECT: <br /> <br />OWNER: <br /> <br />S~TE NUMBER: <br /> <br />TYPE OF CONSTRUCTION: <br /> <br />BUILDING CLASS: <br /> <br /> STRUCTURA~ PL~=NS REVIEW <br /> June 18, 1991 <br /> <br /> 8820 Aumsville Hwy, Aumsville <br /> Jimco Fence co. <br /> 10662 <br /> 5-N <br /> <br /> B-2 (Shop) / B-2 (office) <br /> (3,360 sq.ft.) (936 sq. ft~) <br /> <br />The plans fo~ the above indicated project are acceptable as submitted <br />subject to the following items noted below: <br /> <br />This is a Plan Review covering the construction of the above indicated new <br />building. Plans have been reviewed for compliance with the provisions of the <br />Oregon State Structural specialty Code (UEC) 1990 ~dition. <br /> <br />The area of the building designated as the "SHOP" has been classified as <br />a Group B Division 2 occupancy. If the facility i~ to be used for <br />vehicle repair an occupancy change will be required and additional <br />construction requirements would be imposed. <br /> <br />Details of the construction of the 10 x 16 storage lea~-to are not shown <br />on the plans. The building inspector will field verify the construction <br />details. <br /> <br />Exit doo~s shall be openable from the inside without the use Of a key or <br />any special knowledge or effort, Manually operated edge o~ surface <br />bolts are prohibited. (3304(c)) <br /> <br />Portable fire extinguisher shall be provided and installed as required <br />by applicable ~tandards and as directed by the authority having <br />jurisdiction. (U.F.C. 10.303; U.F.C. Std. No. 10-1) <br /> <br />Toilet room floors shall have a ~mooth, hard, nonabsorbent surface such <br />as portland cement, concrete, ceramic ~ile or oth~ approved material <br />which extends upward onto the walls at least 5 inches. Walls within <br />water closet compartments and walls within 2 feet of the front and sides <br />of urinals shall be similarly finished to a height of 4 feet and, except <br />for structural elements, the materials used in such wall~ shall be of a <br />type which is not adversely affected by moisture. (~10(c)) <br /> <br />The exterior building envelope, heating, ventilating, ai~ conditioning <br />and service water heating system~ shall comply with Chapter 53, Energy <br />Conservation, Submit certification of conformance by an <br />registered architect or engineer. (5301(c}} <br /> <br />Senator Building 220 Fligh Street NE Salem, Oregon 97301-3670 <br /> <br /> <br />