Laserfiche WebLink
11. <br /> <br /> The following regulations apply when lot line adjustments and/or partitioning of land <br /> regulated by the Subdivision and Partition Ordinance are proposed in an AR zone: <br />Lot Area: The minimum lot size for subdivisions and partitioning is 2 acres. When a <br />numerical suffix has been applied to the AR zone, the minimum lot size shall <br />conform to the numerical designation. The minimum lot size shall not apply to <br />planned developments where maximum density calculations are implemented subject <br />to requirements in the Planned Unit Development Regulations section of the Marion <br />County Subdivision and Partition Ordinance. <br /> <br />Development Standards: The following standards apply to development in an AR <br />zone. The height requirements are as follows: <br /> <br />· Maximum Height of a dwelling is 35 feet; <br />· Farm related structures on farm parcels - none; <br />· Non-residential and non-farm structures - 35 feet unless they are in <br /> conjunction with conditional uses allowed in Section 128.030, and a greater <br /> height is requested and approved as part of the conditional use permit. <br /> Except as required in Section 128.050(a), the following setback requirements <br /> shall be implemented for all new structures other than farm-exempt buildings, <br /> signs and fences: <br />· Rear Yard - A minimum of 20 feet. <br />· Side Yard - A minimum of 10 feet, except for lots or parcels of one-half acre <br /> or smaller created prior to January I, 1994, in which case the side yard <br /> setback shall be five (5) feet. In the case of a comer lot any side yard adjacent <br /> to a street shall be not less that 20 feet. <br />· Front Yard - A minimum of 20 feet. When by ordinance a greater setback <br /> or a front yard of greater depth is required than specified in this section, then <br /> such greater setback line or fxont yard depth shall apply (See Section 112). <br />The proposed lots exceed the two-acre minimum required in the AR zone. The <br />standard in//6 is satisfied. The development standards are standards that need to be <br />met at the time of development. <br /> <br />The subject property is located in the Sensitive Groundwater Overlay Zone -5 Acre <br />Minimum. A Water Use Inventory was submitted with the application to show that <br />41.48 percent of the recharge in the area will be consumed by existing uses combined <br />with permitted future residential use. A hydrogeology review was conducted on the <br />property that shows that there is enough recharge to allow for the proposed <br />development. <br /> <br />Based on the above and subject to the required agreements, the proposed partitioning <br />complies with the criteria for a partitioning in the AR zone and is approved. <br /> <br />Craig O. Luedeman <br /> <br />Director-Planning Division <br />Community Development Department <br /> <br />Date: 11-22~02 <br /> <br />If you have any questions please contact Diane Rolph at ~8,~:-~/k Ol'3~tflct <br /> <br /> <br />