AWARNING ELECTRICAL SHOCK HAZARD ! , : : , , EXPLOSION OR FIRE HAZARD <br /> %wit Disconnect power before installing or servicing this Do not use this product with flammable liquids. <br /> product.A qualified service person must install and l ' .�? Do not install in hazardous locations as defined by <br /> service this product according to applicable electrical t<r. ` National Electrical Code,ANSI/NFPA 70. <br /> and plumbing codes. <br /> Failure to follow these precautions could result in serious injury or death. Replace product immediately if switch cable becomes damaged <br /> or severed. Keep these instructions with warranty after installation.This product must be installed in accordance with National Electric Code,ANSI/ <br /> NFPA 70 so as to prevent moisture from entering or accumulating within boxes,conduit bodies,fittings,float housing,or cable. <br /> For detailed specifications on this product, or for the complete line of SJE-Rhombus® <br /> panel, alarm, and switch products, visit our web-site at www.sjerhombus.com. <br /> INSTALLING THE FLOAT SWITCH Figure A <br /> 1. Place the cord into the clamp as shown in Figure A. <br /> 2. Locate the clamp at the desired activation level and secure the p <br /> clamp to the discharge pipe as shown in see Figure A. , ` <br /> Note: Do not install cord under hose clamp. � r� <br /> 3. Tighten the hose clamp using a screwdriver. Over tightening `'� <br /> may result in damage to the plastic clamp. Make sure the float 3.5 inch(9 cm) <br /> cable is not allowed to touch the excess hose clamp band during tether length <br /> operation. <br /> 4. Wire cable leads directly into control device as shown in Figures <br /> B&C. <br /> 5. Check installation.Allow system to cycle to insure proper Figure B - TAX'Standard <br /> operation. Note:All hose clamp components are made of 18-8 <br /> stainless steel material. See your SJE-Rhombus®supplier for F-- <br /> replacements. <br /> INSTALLING THE ALARM o '% <br /> / /I - <br /> 1. Mount alarm box using existing holes in back of box.To ensure (.' 0 I > �° <br /> water-tight seal, use screws and sealing washers included with �� �� o 0 <br /> alarm. Note: Screws are to be located over wall stud or used with 1-float <br /> I I �Gx)l2"Host <br /> a wall anchor sized for a#8 x 1.25 self tapping screw. ITs-neutral <br /> 2. Determine"conduit-in"locations on alarm as shown in Figures B —mid 10 014-Ilse <br /> &C. Note: When used with a pump application, connect alarm (y0-.)____rg oyround <br /> to a circuit separate from the pump circuit.This allows alarm to <br /> continue to operate if the pump circuit fails. ° ! ° <br /> O <br /> 3. Drill holes for conduit entry,taking care not to damage bosses ` <br /> recommended recommendedinside alarm box. power conduit floatwdtah <br /> 4. Attach conduit. In locationlacstion <br /> If alarm includes premounted terminal block option, refer now incoming O 0120 14 <br /> to the Terminal Block Option Wiring Instructions. <br /> 5. Bring float switch cable through conduit and wire to terminal Figure C -TAXI with Auxiliary Contacts <br /> block positions 1 and 2 as shown in Figures B&C. optional auwiiary <br /> --\ <br /> 6. Wire power conductors to terminal block positions 3 and 4 and contacts connection <br /> (see wire labeling) \ <br /> ground wire to ground termination post as shown in Figures B& ,. <br /> C. Note: If terminal block option is used, attach ground wire as C INT�B III <br /> shown in Figure A of Terminal Block Option Wiring Instructions. .Ls i to` °JJ ° <br /> 7. If remote device is used, connect wires as shown in Figure C (di o 110, Qo <br /> „ <br /> using supplied wire nuts. I o' o to of <br /> ,---4.-8. Attach alarm box cover using the four pre-installed screws. ,---4.-1-float <br /> 9. Turn on power. Light on switch should come on. I I I I i12-Host <br /> a-neutral <br /> 10. Check installation by manually tipping the float.The horn and o o :7711 4-line <br /> beacon should turn on. 1001 <br /> 11. Push silence switch to test silence feature. �us� !ground <br /> \'NFU <br /> 12. Test unit once per week to insure proper operation. °L' 0 <br /> o ° <br /> recommended romrmerded <br /> power conduit float/wads <br /> In location conduit In <br /> location <br /> Incoming wire size 14-22 Awg <br /> SJL ' <br /> ombus <br /> 22650 County Highway 6 N P.O. Box 1708 • Detroit Lakes,Minnesota 56502 USA <br /> 1-888-DIAL-SJE(1-888-342-5753) • Phone: 218-847-1317 • Fax: 218-847-4617 • E-mail:sje@sjerhombus.com <br /> Instl.Instr.PN 1024984C Model TAXT ©SJE-Rhombus 08112 <br />