Permit Address
3011 MAHALO CT SE
Permit City
Salem
Permit Number
555-23-001975-PRMT
Parcel Number
083W24A 01800
Permit Type
Septic
Permit Doc Type
Permit Document
Status
Ready to Film
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
S ombus <br /> I <br /> TANK ALERT® XT Alarm Installation Instructions <br /> This alarm system monitors liquid levels in lift pump chambers, sump pump basins, holding tanks, sewage, agricultural, and other <br /> non-potable water applications. <br /> The Tank Alert®XT indoor/outdoor alarm can serve as a high or low level alarm depending on the float switch model used.The <br /> alarm horn sounds and the red beacon illuminates when a potentially threatening liquid level condition occurs.A"power on"light <br /> on the switch indicates power to the alarm panel. <br /> TANK ALERT® XT ALARM <br /> Voltage: 120 VAC, 50/60 Hz, 7 watts maximum(alarm condition) (circuit not supervised) <br /> Enclosure meets Type 3R water-tight standard. <br /> 'Mitt xr <br /> Automatic alarm reset, horn silence switch,and alarm test switch. <br /> / Alarm horn sounds at 85 decibels at 10 feet(3 meters). <br /> / Alarm system(when installed on separate circuit)operates even if pump circuit fails. <br /> Maximum line impedance for initiating device: 100 ohms. <br /> II Complete package includes standard Sensor Float°control switch with 15 feet(4.57 meters)of <br /> cable(other lengths available)and mounting clamp. <br /> ( / Three-year limited warranty. <br /> OPTIONS <br /> When ordered with the alarm,the system Is available with: <br /> alternate float switch models for high or low liquid level warning. <br /> auxiliary alarm contacts for easy attachment of remote devices: (circuit not supervised) 120 VAC, 5 amps max., 50/60 Hz <br /> premounted terminal block so enclosure can also be used as a junction box for splicing pump, pump switch, and pump <br /> power. Meets NEC standard for junction boxes.20 amps, 120/230 VAC. <br /> 6 foot(1.8 meter) power cord with 120 VAC plug and liquid-tight connectors. <br /> PREVENTATIVE MAINTENANCE <br /> • Periodically inspect the product.Check that the cable has not become worn or that the housing has not been damaged so as to impair the protection of the <br /> product.Replace the product immediately if any damage is found or suspected. <br /> • Periodically check to see that the float is free to move and operate the switch. <br /> • Use only SJE-Rhombus®replacement parts. <br /> SJE-RHOMBUS" THREE-YEAR LIMITED WARRANTY <br /> SJE-RHOMBUS®warrants to the original consumer that this product Some states do not allow limitations on how long an implied warranty <br /> shall be free of manufacturing defects for three years after the date of lasts,so the above limitation may not apply to you. Some states do not <br /> consumer purchase. During that time period and subject to the conditions allow the exclusion or limitation of incidental or consequential damages, <br /> set forth below,SJE-RHOMBUS®will repair or replace,for the original so the above limitation or exclusion may not apply to you. This warranty <br /> consumer,any component which proves to be defective due to defective gives you specific legal rights,and you may also have other rights which <br /> materials or workmanship of SJE-RHOMBUS®. vary from state to state. <br /> THIS EXPRESS WARRANTY DOES NOT APPLY TO THE MOTOR TO OBTAIN WARRANTY SERVICE:The consumer shall assume all <br /> START KIT COMPONENT. SJE-RHOMBUS®MAKES NO WARRAN- responsibility and expense for removal, reinstallation,and freight. Any <br /> TIES OF ANY TYPE WITH RESPECT TO THE MOTOR START KIT. item to be repaired or replaced under this warranty must be returned to <br /> SJE-RHOMBUS®,or such place as designated by SJE-RHOMBUS®. <br /> ELECTRICAL WIRING AND SERVICING OF THIS PRODUCT MUST <br /> BE PERFORMED BY A LICENSED ELECTRICIAN. ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS <br /> ARE LIMITED TO THE DURATION OF THIS WRITTEN WARRANTY. <br /> THIS WARRANTY DOES NOT APPLY:(A)to damage due to lightning SJE-RHOMBUS® SHALL NOT, IN ANY MANNER, BE LIABLE FOR <br /> or conditions beyond the control of SJE-RHOMBUS®;(B)to defects or ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES AS A RESULT <br /> malfunctions resulting from failure to properly install,operate or maintain OF A BREACH OF THIS WRITTEN WARRANTY OR ANY IMPLIED <br /> the unit in accordance with printed instructions provided;(C)to failures WARRANTY. <br /> resulting from abuse,misuse,accident,or negligence;(D)to units which <br /> are not installed in accordance with applicable local codes,ordinances, <br /> or accepted trade practices, and (E)to units repaired and/or modified <br /> without prior authorization from SJE-RHOMBUS®. <br />
The URL can be used to link to this page
Your browser does not support the video tag.