Laserfiche WebLink
Pump Selection for a Non-Pressurized System-Single Family Residence Project <br /> Parameters <br /> Discharge Assembly Size 1.25 inches <br /> PF30151 --- <br /> Transport Length 175 feet <br /> Transport Pipe Class 40 <br /> Transport Line Size 1.50 inches <br /> Distributing Valve Model None <br /> Max Elevation Lift 10 feet 250 , — <br /> Design Flow Rate 30 gpm <br /> Flow Meter None inches I PF3010 j <br /> 'Add-on'Friction Losses 0 feet ..._ <br /> Calculations - <br /> Transport Velocity 4.7 fps m 200 I PF3007) <br /> li <br /> Frictional Head Losses o <br /> Loss through Discharge 6.3 feet f <br /> Loss in Transport 9.2 feet co <br /> Loss through Valve 0.0 feet = 150 .,\ <br /> Loss through Flowmeter 0.0 feet v <br /> 'Add-on'Friction Losses 0.0 feet to <br /> c <br /> a' 1 PF3005f <br /> Pipe Volumes <br /> Vol of Transport Line 18.5 gals i2 100 <br /> Minimum Pump Requirements <br /> Design Flow Rate 30.0 gpm <br /> Total Dynamic Head 25.5 feet <br /> 50 <br /> A. <br /> 00 5 10 15 20 25 30 35 40 <br /> Net Discharge(gpm) <br /> PumpData Legend <br /> PF3005 High Head Effluent Pump System Curve: <br /> 30 GPM,1/2HP <br /> 115/230V 10 60Hz,200V 30 60Hz Pump Curve:''—' <br /> PF3007 High Head Effluent Pump Pump Optimal Range:— <br /> 30 GPM,3/4HP <br /> 230V 10 60Hz,200/460V 30 60Hz Operating Point: <br /> PF3010 High Head Effluent Pump Design Point:O <br /> 8 30 GPM,1HP <br /> 230V 10 60Hz,200/460V 30 60Hz <br /> 0 .'.. <br /> Ike <br /> PF3015 High Head Effluent Pump <br /> 30 GPM,1-1/2HP <br /> Oro 230V 10 60Hz,200/230/460V 30 60Hz <br /> Y T E M <br />