Laserfiche WebLink
Onsite Permit 555-20-008461-PRMT-01 Page 2 of 3 <br /> Schedule or track inspections at www.buildingpermits.oregon.gov <br /> Call or text the word "schedule"to 1-888-299-2821 use IVR Number:555043859752 <br /> Schedule using the Oregon ePermitting Inspection App, search"epermitting"in the app store <br /> ��t.�-xsy�'Y�"'#' t � .c � .;••��, y.- `.�.;.m�u7'�""3.,-.�.atr"�rTa � .,-'^s��"'«� ,.e tv '� au,+'�" -*r�.+�.+-c�y.fi '.�`"eTl7 } <br /> Date Iiss 1 d,4/22/2 s i , u ExpiretIon date 4122/22 <br /> Wo t descriptton�iFIRE ,MIN REP'-,REP ACE 3 BURMfSPD WI{ H12a5DRM SFpt , <br /> •� � �ice=`,,�y. � �.r 4 �� fi � �� g,, '�'+ �ij'x {., �r&d k �.�� �'� �`-"� s�.f.-..,�, �,z�. x,� � Z� -�r <br /> Conditions of approval <br /> .This repair permit is for replacement of the existing,yellow Norwesco poly septic tank,which showed signs of <br /> bowing,and may have been installed backwards.The property and dwellling was burnt in the Beachie Creek <br /> Fire of 2020. According to the property owner,the entire septic system was installed in 1992.Marion County <br /> has no permit records for the system,therefore this department has operated under the assumption that it was <br /> installed without a permit. Per OAR 340-071-0185 the system must be decommissioned.However,as a <br /> reasonable reapair,this department has allowed the system to be partially uncovered and inspected to see if it <br /> was installed in accordance with OAR 340-071-0220.The drop box,and the beginning, middle and end of both <br /> lines were uncovered.A laser level was used to verify that the trenches were installed within 1 inch of level.A <br /> test pit was examined to ensure the installation depth(36")was appropriate.The soil consisted of a loam <br /> texture with no limiting layer or temporary water table within 48". <br /> -Properly decommission the old septic tank and submit appropriate documentation. <br /> •The system must be installed by the property owner or a licensed sewage disposal business(installer). <br /> -All tanks must be tested for watertightness and have a water-tight riser to the ground surface.Twenty-inch <br /> minimum diameter if less than 36-in deep.Thirty-inch minimum diameter if greater than 36-in deep.Maintain <br /> access to septic tank for pumping and service. <br /> •A minimum 18-gauge,green jacketed tracer wire or green color-coded metallic tape must be placed on top <br /> of the effluent sewer or pressure transport pipe from tank to drainfield. <br /> -Effluent sewer.The effluent sewer must extend at least 5 feet beyond the septic tank before connecting to <br /> the distribution unit. It must be installed with a minimum fall of 4 inches per 100 feet and at least 2 inches of fall <br /> from one end of the pipe to the other. In addition,there must be a minimum difference of 8 inches between the <br /> invert of the septic tank outlet and either the invert of the header to the distribution pipe of the highest lateral in a <br /> • serial distribution field or the invert of the header pipe to the distribution pipes of an equal distribution absorption <br /> field. <br /> 4/22/21:11:30:54AM Page 2 of 3 ONS_OnsitePermitpr <br />