Laserfiche WebLink
Onsite Permit 555-17-004500-PRMT Page 2 of 3 <br /> Schedule Inspections online at www.builaingpermits.oregon.gov or by calling 1-888499-2821 or 501-388-6575 <br /> 3�when calling for an inspection,use NR Number 555002683819 <br /> D ey Si11:i i3- > rr ' a Y0 ,Oon Date 65 55 <br /> �1 h a kv tKt. <br /> W d" at • nONOR ALTEHX'kYe MbVMS. it• .I' .111N' <br /> Pump to Drainfleld Regd: N/A Filter Fabric on Top of Drain Media: N/A <br /> Rake Trench Sidewalls: N/A <br /> Other Special Rqmt: Not specified <br /> Conditions of Approval <br /> The septic tank installation plan is approved as submitted. Please refer to the signed approved site plan dated June 14, <br /> 2017. Any deviation from the approved plans must be authorized by this office prior to installation or the permit may be <br /> voided. <br /> SEPTIC TANK: 1000-gallon minimum <br /> -ANTIBOUVANCV IS REQUIRED AT THIS LOCATION. Install as per manufacturer's instructions listed on the Oregon DEQ <br /> website. <br /> PLASTIC TANK INSTALLATION REQUIREMENTS: Install as per manufacturer's instruction listed on Oregon DEO <br /> website. <br /> TANK RISER: The tank must be installed with watertight risers extending to the ground surface or above. The riser lids <br /> must be gasketed and securely fastened. <br /> EFFLUENT SEWER: The effluent sewer is the pipe from the septic tank to the distribution box. The material required is <br /> 3034 or Schedule 40 pipe with 18-gauge minimum green tracer wire or green metallic tape placed along the pipe. The effluent <br /> sewer shall extend at least five(5)feet from the tank. There must be a minimum difference of eight(8)inches between the <br /> invert(flow line)of the septic tank outlet and the invert of the distribution or drop box outlet. In Equal Distribution,there must <br /> be six(6)inches of fall between the septic tank outlet and the distribution box inlet. In Serial Distribution,there must be two(2) <br /> inches of fall between the septic tank outlet and the drop box inlet. <br /> .OBSERVE ALL SETBACKS AND SEPARATION DISTANCES as required by the DEQ rules. A copy of the DEQ setback <br /> requirements is available in our office and online at http-..//www.oregon.gov/deq/Residential/Pages/Onsite.aspx under Rules: <br /> Division 71'.Table 1. <br /> -THE ATTACHED SEPTIC TANK ABANDONMENT FORM MUST BE COMPLETED AND RETURNED TO OUR OFFICE. <br /> The septic system installer must complete and sign the form and attach a copy of the receipt from the septic tank pumping <br /> service for pumping the tank. <br /> MAINTAIN PERMANENT ACCESS to septic tank for pumping and service. The septic tank should be pumped and <br /> inspected by a licensed septic tank pumping service before sludge and scum accumulations reach 30%of the tank <br /> liquid operating volume. Pumping every 3 to 5 years is an average interval. The septic tank is a reservoir for the solid <br /> materials in the sewage waste stream. Excessive accumulation of these solid materials in the septic tank will cause the solids <br /> to wash out of the tank and into the drainfield. This will cause irreversible damage to the drainfield and will eventually lead to a <br /> system failure. <br /> CALL BEFORE you DIG.-IT'S THE LAW <br /> orrororioN Grebe,' you to roma..rums adopted by Mb°ebbed,Utility Nvnmm�ov Center Thoseby O ec on mmnisvamn Rwex. You may obtain copra <br /> of rues by cooing ne ente.(Note:Thetelepbore number kr the otrym utility notification Cenm sa.eoo-332-2344) <br /> 6/15/17:3'.39:28PM Page 2 of 3 C:\myneports/reports//production/O1 STANDARD <br /> REPORTS/stdOnsitepermit_v2_pr rpt <br />