pipe. The gravel must be covered with filter fabric. When curtain drain outlet piping is covered by less <br /> than 12 inches of soil,pipe must meet or exceed ASTM Standard D-3034. The outlet must be fitted with <br /> a flap gate or rodent guard. The curtain drain must be located at least 10 feet up slope from the disposal <br /> field and must discharge through a watertight non-perforated pipe beside or below the disposal field. A <br /> minimum separation of 10 feet is required from the septic tank if the tank is located up slope of the <br /> curtain drain and 5 feet if the tank is located down slope of the curtain drain. <br /> A CAPPING FILL DRAINFIELD IS REQUIRED in conjunction with the attached septic system <br /> approval. CAPPING FILL systems are installed in soils where a layer that limits the effective soil depth <br /> or a water table is present in the soil profile at a depth shallower than allowed for a standard system.The <br /> DISPOSAL TRENCHES are installed at a VERY SHALLOW DEPTH and APPROVED FILL is placed <br /> over the trenches to provide earth cover over the system. Fill material must be evenly graded over the <br /> DRAINFIELD and crowned at the center to shed rainfall.CAPPING FILL SYSTEMS MAY ONLY BE <br /> INSTALLED FROM JUNE 1 AND OCTOBER I or during such times when the Building Inspection <br /> Onsite Wastewater staff finds soil moisture conditions acceptable. See the attached"CAPPING FILL" <br /> information sheet for instructions. NOTE: GRA VELLESS ABSORPTION TRENCHES MAY BE <br /> INSTALLED IN LIEU of the CAPPING FILL DRAINFIELD. <br /> A DETAILED SEPTIC SYSTEM STAKEOUT IS REQUIRED prior to the issuance of a septic system <br /> installation permit. The area for the system is very limited and the stakeout must be completed to • <br /> determine that the system will fit within the area of the approved test pits. A scale drawn, detailed site <br /> plan must b submitted with the application for the installation permit.The stakeout must be inspected on <br /> the property and approved before the permit can be issued.Instructions for the stakeout are attached and <br /> are available in our office. <br /> Additional Conditions of Site Approval <br /> 1. This site is approved for the type of disposal system described above. Peak sewage flow into the <br /> system is limited to a maximum of 450 gallons per day, with an average sewage flow of not more <br /> than 225 gallons per day. This is normally sufficient to serve a single family dwelling with a <br /> maximum of four bedrooms. Premature failure of the treatment system may occur if either of these <br /> flow quantities is exceeded. Iffor some reason you expect your domestic household water use may <br /> exceed these flows, it may be advisable to increase the size of the treatment system. <br /> 2. Any alteration of natural soil conditions(i.e. cutting or filling) in the acceptable area may void this <br /> approval. <br /> 3. Both the initial and replacement disposal areas are to be protected from traffic,livestock and farming <br /> activities, development or other potential disturbance of natural soil conditions. <br /> 4. The area must not be subjected to excessive saturation due to,but not limited to, artificial drainage <br /> of ground surfaces, roads, driveways and building down spouts. <br /> 5. This approval is given on the basis that the parcel described above will not be further partitioned or <br /> subdivided. <br /> 6. Placement of a well within 100 feet of the approved areas may invalidate this approval. <br /> This site approval is valid until the system approved above is constructed in accordance with a Marion <br /> 555 Court St NE - P.O.Box 14500-Salem,Oregon 97309-5036-Phone(503)588-5147-Fax(503)588-7948 <br /> Page 3 of 4 <br />