STRUCTURAL NOTES <br />GENERAL REQUIREMENTS: <br />MATERIALS ARE TO BE HANDLED, STORED AND INSTALLED IN STRICT COMPLIANCE WITH THE MANUFACTURER'S <br />RECOMMENDATIONS. <br />CONTRACTOR IS RESPONSIBLE FOR TEMPORARY SHORING AND BRACING REQUIRED BY THE WORK. <br />CONTRACTOR TO VERIFY EXISTING SITE CONDITIONS AND DIMENSIONS PRIOR TO CONSTRUCTION. <br />THE STRUCTURAL DRAWINGS DO NOT REFLECT ALL OPENINGS THAT MAY BE REQUIRED FOR DUCTS, <br />PIPES OR CONDUITS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE OPENINGS <br />WITH STRUCTURAL REQUIREMENTS. STRUCTURAL MEMBERS SHALL NOT BE CUT OR NOTCHED <br />WITHOUT ENGINEER APPROVAL. <br />ALL DETAILS AND NOTES DESIGNATED AS TYPICAL SHALL APPLY TO THE CONSTRUCTION OF THE <br />PROJECT UNLESS NOTED OTHERWISE. CONDITIONS NOT SPECIFICALLY DETAILED SHALL BE IN <br />GENERAL CONFORMANCE WITH CONSTRUCTION DETAILS OF A SIMILAR NATURE USED ELSEWHERE <br />ON THE PROJECT. <br />THE CONTRACT DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE AND DO <br />NOT INDICATE METHODS, PROCEDURES, OR SEQUENCE OF CONSTRUCTION UNLESS NOTED OTHERWISE. <br />THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO MAINTAIN AND INSURE THE INTEGRITY <br />OF THE STRUCTURE DURING CONSTRCTION. <br />51TE WORK <br />- SUBBASE FOR FOOTINGS, GRADE BEAMS AND SLABS SHALL BE ENGINEERED FILL OR UNDISTURBED NATIVE <br />SOIL DEVOID OF ANY ORGANIC MATERIAL. <br />- BASE FOR SLABS SHALL BE A 4" LAYER OF ENGINEERED FILL. SEE ARCH DWGS FOR VAPOR RETARDER <br />AND INSULATION REQUIREMENTS. <br />- ENGINEERED FILL: 3/4" MINUS CRUSHED ROCK COMPACTED TO %% MAX DRY DENSITY AS PER ASTM DI557, <br />PLACED IN 4" LIFTS. <br />CONCRETE: <br />- READY MIXED, ASTM C -g4 * ASTM C-260 <br />- FOOTINGS, STEM WALLS, FLOOR SLABS: <br />STRENGTH f'c= 3500 PSI MINIMUM @ 28 DAYS <br />TESTING IS REQUIRED <br />- 4" MAX. SLUMP WITHOUT USE OF SUPERPLASTICIZER <br />- ALLOW CONCRETE TO CURE A MINIMUM OF 14 DAYS BEFORE BACKFILLING WALLS. <br />- DO NOT ALLOW ANY HEAVY EQUIPMENT ANY CLOSER TO THE TOP OF A RETAINING WALL THAN <br />THE HEIGHT OF THE WALL. <br />- ALL CONCRETE WORK SHALL BE PRODUCED, PLACED, CONSOLIDATED, CURED, AND FINISHED IN <br />CONFORMANCE WITH ACI STANDARDS 301, 305, AND 306. CALCIUM CHLORIDE, SALT, OR OTHER MATERIALS <br />CREATING A CORROSIVE ENVIRONMENT IN THE CONCRETE SHALL NOT BE USED FOR ANY REASON. <br />- WHERE A CONCRETE SURFACE IS TO BE ROUGHENED, THE SURFACE SHALL HAVE A FULL AMPLITUDE OF <br />APPROXIMATELY 1/4 INCH. THE RESULTING SURFACE SHALL BE CLEAN AND FREE OF LAITANCE AND LOOSE <br />MATERIAL. IMMEDIATELY BEFORE NEW CONCRETE 15 PLACED, THE INTERFACE SURFACE SHALL BE <br />THOROUGHLY WETTED AND STANDING WATER REMOVED. <br />- CONTROL JOINTS MADE BY SAWING SHALL BE MADE AS SOON AS THE CONCRETE SURFACE 15 FIRM ENOUGH <br />TO NOT BE TORN OR DAMAGED BY THE BLADE AND BEFORE RANDOM SHRINKAGE CRACKS CAN FORM IN THE <br />CONCRETE SLAB. AT WALLS AND OTHER PLACES WHERE THE SAW CANNOT GET INTO THE CORNER, TOOLED <br />OR FORMED JOINTS SHALL BE PROVIDED TO COMPLETE THE CONTROL JOINT. <br />- ALL DETAILING, CONCRETE PLACEMENT, BAR SUPPORTS, ETC., SHALL COMPLY WITH THE PROVISIONS AND <br />RECOMMENDATIONS CONTAINED IN THE "MANUAL OF STANDARD PRACTICE", BY THE CONCRETE REINFORCING <br />STEEL INSTITUTE. <br />- SLEEVES, OPENINGS, OR OTHER ATTACHMENTS NOT SHOWN ON THE DRAWINGS SHALL BE APPROVED BY <br />THE ENGINEER PRIOR TO CONSTRUCTION. <br />STEEL REINFORCEMENT: <br />- ASTM A-615 GRADE 60. PLACE PER ACI CODES AND STANDARDS. <br />- SPLICES MINIMUM #5 - 30" LAP, #4 - 24" LAP, #3 - IS" LAP <br />- REINFORCING SHALL BE DETAILED, FABRICATED, AND PLACED IN ACCORDANCE WITH ACI 315. <br />- REINFORCING SHALL BE ACCURATELY AND SECURELY PLACED. <br />- REINFORCING IN CAST IN PLACE CONCRETE THAT IS CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH <br />SHALL HAVE A MINIMUM OF 3 INCHES OF CONCRETE COVER. <br />- REINFORCING EXPOSED TO EARTH OR WEATHER, BUT NOT CAST AGAINST EARTH, SHALL HAVE A MINIMUM OF <br />2 INCHES OF CONCRETE COVER. <br />- REINFORCING NOT EXPOSED TO WEATHER OR CONTACT WITH EARTH SHALL HAVE A MINIMUM OF 1-1/2 INCHES <br />OF CONCRETE COVER. <br />- REINFORCING BARS ARE NOT TO BE RESENT WITHOUT APPROVAL OF THE STRUCTURAL ENGINEER. <br />CAST -IN-PLACE ANCHOR BOLTS: <br />- HEADED BOLTS SHALL BE ASTM F1554 OR A307 <br />- THREADED ROD SHALL BE A36 <br />- THREADED ROD MAY BE EITHER SMOOTH ROD WITH THREADED ENDS OR ALL -THREAD. <br />- L -BOLTS MAY NOT BE USED WHERE HEADED BOLTS ARE SHOWN. <br />- WASHER AT EMBEDDED HEAD SHALL BE SECURED WITH TACK WELD OR ADHESIVE TO PREVENT SEPARATION FROM HEAD <br />DURING CONCRETE POUR. <br />SIMPSON TITEN HD ANCHORS: <br />- DESIGN 15 PER IGC REPORT ESR -2713. <br />- INSTALL PER MANUFACTURER'S INSTRUCTIONS. <br />- DO NOT EXCEED THE MAXIMUM INSTALLATION TORQUE LISTED IN REPORT FOR DIAMETER USED. <br />WOOD FRAMING: <br />I. CONSTRUCTION: <br />- WOOD CONSTRUCTION PER OSSC 2304 AND 2308 CONVENTIONAL CONSTRUCTION PROVISIONS AND FASTENING SCHEDULE, <br />UNO. <br />2. EVIDENCE OF GRADE: <br />- GRADE MARK OF AN APPROVED GRADING ORGANIZATION HAVING JURISDICTION MUST APPEAR ON EACH PIECE OF <br />MATERIAL. <br />3. FRAMING LUMBER: <br />- DOUGLAS FIR/LARCH, 545, TO STANDARD DIMENSIONS <br />- 2 X 4 PARTITION WALL <br />STUDS - STUD GRADE OR BETTER U.N.O. <br />- 2 X 6 STUDS - #2 GRADE OR BETTER U.N.O. <br />- 2 X FRAMING - #2 GRADE OR BETTER U.N.O. <br />- 4 X FRAMING - #2 GRADE OR BETTER U.N.O. <br />- 6 X FRAMING - #1 GRADE OR BETTER U.N.O. <br />- FURRING AND BLOCKING - #3 GRADE OR BETTER <br />4. TREATED WOOD: <br />- SOLE PLATES BEARING ON CONCRETE (MUD SILLS) SHALL BE TREATED WITH WATERBORNE PRESERVATIVES IN <br />ACCORDANCE WITH AWPA STANDARD UI TO THE REQUIREMENTS OF USE CATEGORY 2 (UC2). #2 HEMLOCK MAY BE USED. <br />- ALL FASTENERS AND HARDWARE IN CONTACT WITH TREATED WOOD SHALL BE HOT DIP GALVANIZED. <br />(ANCHOR RODS FOR TIE -DOWNS DO NOT NEED TO BE GALVANIZED. PROVIDE OVERSIZE HOLE IN MUDSILL TO PREVENT <br />CONTACT.) <br />8. EXTERIOR WALL SHEATHING: <br />-15/32" APA RATED PLYWOOD (NOT OSB) SHEATHING EXPOSURE I <br />EXTERIOR WALLS NOT DESIGNATED AS SHEAR WALLS SHALL BE SHEATHED AS TYPE ZERO SHEAR WALLS. <br />6. ROOF SHEATHING: <br />- 1`Y32" APA RATED PLYWOOD (NOT OSB) SHEATHING, EXPOSURE I. <br />- PLACE PANELS PERPENDICULAR TO FRAMING, WITH END JOINTS STAGGERED 4'-01'. <br />q. GLUE LAMINATED MEMBERS- <br />- SHALL BE MANUFACTURED AND IDENTIFIED PER ANSI/AITC AlgO.I AND ASTM D3737. <br />- MEMBERS SHALL BE 24F -V4, UNLESS OTHERWISE NOTED. <br />- GLUE LAMINATED MEMBERS SHALL BE NOTCHED, SHAPED AND FINISHED PER PLANS AND SPECIFICATIONS <br />- ERECTION OF MEMBERS SHALL CONFORM TO AITC SPECIFICATIONS. <br />- FABRICATE WITHOUT CAMBER. <br />- EXTERIOR GLULAM BEAMS AND COLUMNS SHALL BE ROSBORO TREATED X -BEAM, ARCHITECTURAL APPEARANCE. <br />10. ENGINEERED WOOD MEMBERS: <br />NOT USED <br />11. ROOF TRUSSES SHALL BE ENGINEERED BY THE MANUFACTURER. <br />12. CONNECTORS: <br />- CONNECTORS CALLED OUT ARE BY SIMPSON STRONG -TIE, U.N.O. <br />- USE FASTENERS LISTED IN SIMPSON CONNECTOR CATALOG, U.N.O. <br />- SEE FASTENING SCHEDULE FOR CONNECTIONS NOT SPECIFIED IN DETAILS <br />DESIGN CRITERIA <br />RISK CATEGORY: II (BLDG STRENGTH DESIGNED AT CATEGORY IV, BUT DUE TO BUDGET <br />CONSTRAINT, NOT REQUIRING ADDITIONAL INSPECTIONS AND STRUCTURAL OBSERVATION <br />ASSOCIATED WITH CATEGORY IV) <br />ROOF LIVE LOAD: 20 PSF <br />ROOF SNOW LOAD: 25 PSF (INCLUDES 5 PSF RAIN -ON -SNOW SURCHARGE) <br />SEE SNOW LOAD PLAN FOR DRIFT SNOW LOAD <br />ALLOWABLE SOIL BEARING: 1500 PSF <br />WIND: <br />Vult = 130 MPH <br />EXPOSURE: C IN ALL DIRECTIONS <br />INTERNAL PRESSURE COEFFICIENT GCpi = f 0.18 (ENCLOSED BLDG) <br />SEISMIC: <br />IMPORTANCE FACTOR le = 1.5 <br />MAPPED SPECTRAL RESPONSE ACCELERATION FACTORS: Ss = 0.88 51 = 0.42 <br />51TE CLASS: D <br />DESIGN SPECTRAL RESPONSE ACCELERATION FACTORS: Sds = 0.68 Shc = 0.45 <br />SEISMIC DESIGN CATEGORY: D <br />ANALYSIS PROCEDURE USED: EQUIVALENT LATERAL FORCE <br />BASIC SEISMIC FORCE -RESISTING SYSTEM: <br />LIGHT FRAMED WALLS WITH WOOD PANEL SHEATHING <br />RESPONSE MODIFICATION COEFFICIENT R = 6.5 <br />SEISMIC RESPONSE COEFFICIENT Cs = 0.16 <br />DEFERRED SUBMITTALS <br />ENGINEERING DESIGN FOR THE FOLLOWING ITEMS 15 NOT INCLUDED IN THESE PLANS. <br />THE CONTRACTOR'S SUPPLIER SHALL PROVIDE ENGINEERED PLANS AND CALCULATIONS, <br />WHICH WILL BE REVIEWED BY ANG ENGINEERING FOR CONFORMANCE AND THEN <br />SUBMITTED TO THE BUILDING DEPARTMENT. THESE ITEMS SHALL NOT BE INSTALLED <br />BEFORE APPROVAL BY BUILDING DEPARTMENT. <br />MANUFACTURED WOOD TRUSSES <br />SPECIAL INSPECTIONS $ TESTING <br />I. THE FOLLOWING WORK 15 REQUIRED - IF MARKED - TO BE TESTED AND/OR SPECIAL INSPECTED, <br />PER OSSC CHAPTER 17 REQUIREMENTS. <br />2. TESTING SHALL BE MADE IN ACCORDANCE WITH THE CURRENT CODE BY AN APPROVED SPECIAL <br />TESTING LAB, SPECIAL INSPECTOR AND OR BY AN ENGINEER RETAINED BY THE OWNER. <br />3. IF COMPACTED FILL IS REQUIRED, COMPACTION TESTING AND GRADING OPERATIONS SHALL <br />BE OBSERVED BY A GEOTECHNICAL ENGINEER. <br />4. REPORTS SHALL BE SUBMITTED TO THE OWNER, ARCHITECT AND STRUCTURAL ENGINEER. <br />S. BEFORE REQUESTING FINAL INSPECTION, EACH TESTING AGENCY, OR APPROVED FABRICATOR <br />IF APPLICABLE, SHALL SUBMIT A FINAL SIGNED REPORT STATING THAT THE WORK REQUIRING <br />SPECIAL INSPECTION WAS, TO THE BEST OF THE TESTING AGENCY'S OR APPROVED <br />FABRICATOR'S KNOWLEDGE, IN CONFORMANCE TO THE APPROVED PLANS AND SPECIFICATIONS <br />AND THE APPLICABLE WORKMANSHIP PROVISIONS OF THE OSSC. <br />ITEM <br />ACTION TO BE PROVIDED IF MARKED (X) <br />TESTING <br />SPECIAL INSPECTION <br />PART TIME CONTINUOUS <br />51TEWORK <br />(2) 16d FACE NAIL <br />STUD TO TOP PLATE AND SOLE PLATE <br />(4) 8d TOE NAIL OR (2) 16d END NAIL <br />FOUNDATION EXCAVATED SURFACE <br />(2) 8d TOE NAIL <br />X (G) <br />CENTER LINE <br />STRUCTURAL FILLS <br />X (G) <br />CMU <br />CONCRETE MASONRY UNIT <br />COL <br />COLUMN <br />CONT <br />CONTINUOUS <br />RF;INEQRCE12 CON A I <br />DOUBLE <br />DF -L <br />DOUGLAS FIR -LARCH <br />FORMWORK DIMENSIONS <br />DIAGONAL <br />X <br />DIAMETER 0 <br />REINFORCING PLACEMENT <br />EXISTING <br />X <br />ELEVATION <br />ANCHOR BOLT PLACEMENT <br />EDGE NAILING <br />X <br />EXTERIOR <br />CONCRETE PLACEMENT <br />FACE OF CONCRETE <br />X <br />FACE OF FRAMING <br />CONCRETE STRENGTH TESTING <br />X <br />GLB <br />GLULAM BEAM <br />GLC <br />GLULAM COLUMN <br />GYP BD <br />GYPSUM BOARD <br />OS -INS A CONC991E ANCHORS <br />5Y2 x 15 <br />24F -V4 <br />SIMPSON TITEN HD ANCHORS <br />X <br />(G) PERFORMED OR OVERSEEN BY GEOTECHNICAL ENGINEER <br />WOOD FRAMING FASTENING SCHEDULE <br />BLOCKING TO TRUSS OR JOIST <br />(4) 8d TOE NAIL EACH END <br />BLOCKING TO TOP PLATE OR BEAM <br />(3) 8d TOE NAIL @ 16" O.G. OR <br />(4) 8d TOE NAIL @ 24" O.G. <br />DOUBLE TOP PLATE CORNER LAP <br />(2) 16d FACE NAIL <br />STUD TO TOP PLATE AND SOLE PLATE <br />(4) 8d TOE NAIL OR (2) 16d END NAIL <br />TRUSS OR JOIST TO TOP PLATE <br />(2) 8d TOE NAIL <br />4'-0" <br />CENTER LINE <br />NAIL t SCREW SIZE CHART <br />8d COMMON = 0.131"(P x 2.5" SIMPSON SDI -45: 0.22"0 (TIMBER SCREW) <br />10d COMMON = 0.148"(P x 3" SIMPSON SDS: 1/4"(P (HEAVY DUTY CONNECTOR SCREW) <br />12d SINKER = 0.135"0 x 3.25" <br />16d COMMON = 0.162"(P x 3.5" <br />20d COMMON = O.lg2"(P x 4" <br />ABBREVIATIONS <br />ARCH <br />ARCHITECTURAL DRAWINGS <br />BO <br />BOTTOM OF <br />B.N. <br />BOUNDARY NAILING <br />BRG <br />BEARING <br />CANT <br />CANTILEVER <br />4'-0" <br />CENTER LINE <br />CLR <br />CLEAR <br />CMU <br />CONCRETE MASONRY UNIT <br />COL <br />COLUMN <br />CONT <br />CONTINUOUS <br />DBL <br />DOUBLE <br />DF -L <br />DOUGLAS FIR -LARCH <br />DIAL <br />DIAGONAL <br />DIA <br />DIAMETER 0 <br />(E) <br />EXISTING <br />ELEV <br />ELEVATION <br />E.N. <br />EDGE NAILING <br />EXT <br />EXTERIOR <br />FOG <br />FACE OF CONCRETE <br />FOF <br />FACE OF FRAMING <br />GA <br />GAUGE <br />GLB <br />GLULAM BEAM <br />GLC <br />GLULAM COLUMN <br />GYP BD <br />GYPSUM BOARD <br />LSL LAMINATED STRAND LUMBER <br />MAX MAXIMUM <br />MIN MINIMUM <br />MFGD MANUFACTURED <br />MFGR MANUFACTURER <br />OC ON CENTER <br />PL PLATE <br />PERP PERPENDICULAR <br />SD SLOPE DISTANCE <br />SIM SIMILAR <br />SQ SQUARE <br />SPA SPACES <br />STD STANDARD <br />STR STRUCTURAL <br />51,45 SHEAR WALL SCHEDULE <br />THRID THREADED <br />TO TOP OF <br />TRANS TRANSVERSE <br />TYP TYPICAL <br />UNO UNLESS NOTED OTHERWISE <br />LAP SPLICE SCHEDULE <br />FACE NAIL <br />LAP SPLICES <br />PER SCHEDULE <br />CONTINUOUS <br />UPPER PLATE <br />CONTINUOUS <br />LOWER PLATE <br />BETWEEN LAP SPLICES: <br />FACE NAIL WITH 12d SINKER @ 16" OC STAGGERED <br />TOP PLATE SPLICE REQUIREMENTS: <br />ALL BEARING WALLS PERPENDICULAR TO ROOF TRUSSES SHALL HAVE DOUBLE <br />TOP PLATE CONTINUITY PROVIDED BY LAP SPLICES. <br />THE CONTINUOUS PLATE ALTERNATES BETWEEN THE UPPER AND LOWER PLATE. <br />NAILS LONGER THAN 3" ARE SPECIFIED SO THAT NAILING CAN BE EASILY <br />VERIFIED BY FRAMING INSPECTOR. <br />FRAMING ABOVE t BELOW DOUBLE TOP PLATE <br />NOT SHOWN FOR CLARITY <br />BEARING WALL DOUBLE TOP PLATE SPLICE - AXONO\ f .ETR I C VIEW <br />MINIMUM <br />GRADE <br />LOCATION <br />LAP SPLICE <br />FACE NAILS <br />O <br />LENGTH <br />#2 DF -L <br />LOWER ROOF <br />4'-0" <br />(16) 12d SINKER STAGGERED <br />UPPER ROOF <br />6'-0" <br />(24) 12d SINKER STAGGERED <br />FACE NAIL <br />LAP SPLICES <br />PER SCHEDULE <br />CONTINUOUS <br />UPPER PLATE <br />CONTINUOUS <br />LOWER PLATE <br />BETWEEN LAP SPLICES: <br />FACE NAIL WITH 12d SINKER @ 16" OC STAGGERED <br />TOP PLATE SPLICE REQUIREMENTS: <br />ALL BEARING WALLS PERPENDICULAR TO ROOF TRUSSES SHALL HAVE DOUBLE <br />TOP PLATE CONTINUITY PROVIDED BY LAP SPLICES. <br />THE CONTINUOUS PLATE ALTERNATES BETWEEN THE UPPER AND LOWER PLATE. <br />NAILS LONGER THAN 3" ARE SPECIFIED SO THAT NAILING CAN BE EASILY <br />VERIFIED BY FRAMING INSPECTOR. <br />FRAMING ABOVE t BELOW DOUBLE TOP PLATE <br />NOT SHOWN FOR CLARITY <br />BEARING WALL DOUBLE TOP PLATE SPLICE - AXONO\ f .ETR I C VIEW <br />HOLE PATTERN IS ASYMMETRICAL <br />TO MINIMIZE SPLITTING OF WOOD <br />WHEN CLIPS ARE BACK TO BACK. <br />L3x2x3/16 <br />WITH 17/64"(P HOLES <br />HEAVY ANGLE CLIP FOR HEADERS <br />SCALE : 3" = 1'-0" <br />HEADER SCHEDULE <br />TAG <br />SECTION <br />GRADE <br />O <br />1 <br />TRIMMER <br />c <br />O <br />2x6 FLAT <br />#2 DF -L <br />HOLE PATTERN IS ASYMMETRICAL <br />TO MINIMIZE SPLITTING OF WOOD <br />WHEN CLIPS ARE BACK TO BACK. <br />L3x2x3/16 <br />WITH 17/64"(P HOLES <br />HEAVY ANGLE CLIP FOR HEADERS <br />SCALE : 3" = 1'-0" <br />HEADER SCHEDULE <br />TAG <br />SECTION <br />GRADE <br />KING <br />TRIMMER <br />DETAIL <br />H1 <br />2x6 FLAT <br />#2 DF -L <br />(1) 2x6 <br />NONE <br />B <br />SCREWS TO KING <br />* (2) 2-1/2" SDS <br />H3 <br />4x6 FLAT <br />#2 DF -L <br />(2) 2x6 <br />NONE <br />C <br />H4 <br />4x6 FLAT <br />#2 DF -L <br />(1) 2x6 <br />(1) 2x6 <br />A <br />H5 <br />6x6 <br />#2 DF -L <br />(1) 2x6 <br />(1) 2x6 <br />A <br />H6 <br />38'2 x 7Y2 <br />24F -V4 <br />(1) 2x6 <br />(1) 2x6 <br />A <br />H7 <br />5Y2 x Cl <br />24F -V4 <br />(2) 2x6 <br />(1) 2x6 <br />D <br />H5 <br />5Y2 x 15 <br />24F -V4 <br />(2) 2x6 <br />j <br />LL 1 -%1 L t1 <br />HEADER FRAMING ELEVATIONS <br />KING STUD <br />HEADER <br />�L50 CLIP <br />--ANO TRIMMER <br />DETAIL B <br />SCALE : 1/2" = I'-0" <br />A B C C.8 ET <br />/171\ <br />IV <br />�3� LOWER ROOFS SNOW LOAD PLAN <br />KING STUD <br />HEAVY ANGLE CLIP PER DETAIL <br />WITH (4) SDS Ix 2-1/2 <br />SCREWS TO KING <br />t (2) SDS I/4 x 2-I/2" <br />SCREWS TO HEADER <br />TRIMMER <br />DETAIL D <br />TAIL <br />SCALE : 1 1/2" = 1'-0" <br />SCALE : 1/16" = 1'-0" <br />GROUP <br />A E GROUP <br />CIVIL & <br />STRUCTURAL <br />ENGINEERING <br />1355 OAK STREET <br />SUITE 200 <br />EUGENE, OR 97401 <br />(541) 341-1332 <br />ca <br />V_ <br />CQ <br />CIL D <br />CIL <br />z <br />,O <br />( / <br />Lu <br />LL <br />Lu <br />1 <br />PROJECT: E2035 <br />DRAWN: SNS <br />DATE: 4/17/2017 <br />REV: 5/25/2017 <br />SHEET TITLE: <br />STRUCTURAL <br />NOTES <br />SHEET NUMBER: <br />si * 1 <br />HEADER <br />HEAVY ANGLE CLIP PER D <br />WITH (4) 2 1/2" SDS <br />SCREWS TO KING <br />* (2) 2-1/2" SDS <br />SCREWS TO HEADER <br />NO TRIMMER <br />-KING STUD <br />TAIL <br />SCALE : 1 1/2" = 1'-0" <br />SCALE : 1/16" = 1'-0" <br />GROUP <br />A E GROUP <br />CIVIL & <br />STRUCTURAL <br />ENGINEERING <br />1355 OAK STREET <br />SUITE 200 <br />EUGENE, OR 97401 <br />(541) 341-1332 <br />ca <br />V_ <br />CQ <br />CIL D <br />CIL <br />z <br />,O <br />( / <br />Lu <br />LL <br />Lu <br />1 <br />PROJECT: E2035 <br />DRAWN: SNS <br />DATE: 4/17/2017 <br />REV: 5/25/2017 <br />SHEET TITLE: <br />STRUCTURAL <br />NOTES <br />SHEET NUMBER: <br />si * 1 <br />