Laserfiche WebLink
Septic Site Evaluation 555-19-004472-EVAL Page 4 of 6 <br /> Date issued:071 012019 �r� yy -W IS" <br /> ":4A144:#0741"': <br /> �,,,.. +� e �{3 ,3���t" 1 s: *fix t1a .r -� �t�,��-` <br /> ,x i ``s"' tea":# s rr, ,,.c cF� <br /> Applicationsstatus Site E aluatto Appea red M; r <br /> forwr <br /> Uttork description��S P ROPOSED 4�BDRM`rS <br /> � � ei, � �� f` ' ' `" ' �" ,� aa,x.14.4 <br /> ._"*,. .-,r'_ itiiM4t ? �,z� �,'�"...r',`� :$.' "s ., ? . a ,.,.� .ter ' m - _ .ift1#3r <br /> General Description of Site Evaluations <br /> Sewage contains disease-causing organisms and other pollutants that can cause adverse impacts to human health and the <br /> environment. An onsite sewage disposal system must treat and dispose of sewage in a way that will not cause a public <br /> health hazard,contaminate drinking water supplies, or pollute public waters. <br /> Proper treatment in an onsite system begins with primary treatment in the septic tank. The septic tank separates the solid <br /> particles in sewage from the liquid. The liquid that comes out of the septic tank is called effluent. The effluent may then be <br /> dispersed in the soil for further treatment or discharged into a secondary treatment device such as a sand or gravel filter or <br /> other alternative treatment unit prior to dispersal in the soil. For proper treatment,the effluent must slowly infiltrate into the <br /> underlying soil. Dissolved wastes and bacteria in the effluent are trapped or adsorbed to soil particles or decomposed by <br /> microorganisms. This process removes disease-causing organisms, organic matter, and most nutrients. Effluent that <br /> comes to the ground surface(through poor soils or other problems with the system)can be a possible health hazard <br /> because it may still contain some disease-causing organisms. Soil that drains too quickly may not give the effluent enough <br /> treatment and may result in groundwater contamination. <br /> The purpose of the evaluation is to locate suitable soils in an area that is large enough for both the initial drainfield area and <br /> the replacement drainfield area. The criteria used for this site evaluation can be found in Oregon Administrative Rules <br /> (OAR)340-071. <br /> In the site inspection,the following features are evaluated: - <br /> -Soil types-how well they drain and other indicators of good soil structure for treatment <br /> -Depth to evidence of groundwater <br /> -Wells located on the site or adjacent sites <br /> -Slopes,escarpments,ground surface variations,topography <br /> -Creeks or springs on the site or adjacent properties <br /> -Whether the soils have been disturbed <br /> -Setbacks from property lines, buildings,water lines, and other utilities <br /> -Other site features that could affect the placement of your onsite system <br /> Approved Area&System Type <br /> Soil test pits and other site features were evaluated during site visits on July 1,2019. The conditions observed during these <br /> site evaluations indicate that the area around the evaluated test pits IS CAPABLE of supporting a STANDARD SEPTIC <br /> SYSTEM for the INITIAL and an ALTERNATIVE TREATMENT SYSTEM for the REPAIR,due to the lack of space <br /> available. Please refer to the approved site plan dated July 9,2019. <br /> Specific Requirements <br /> Refer to the Soil Notes/Site Evaluation Worksheet which shows the approved areas and other details of the site visit. <br /> A DETAILED SEPTIC SYSTEM STAKEOUT OF THE INITIAL SYSTEM IS REQUIRED prior to the issuance of a septic <br /> system installation permit. A scale drawn,detailed site plan must be submitted with the application for the installation <br /> permit. The stakeout must be inspected on the property and approved before the permit can be issued. Instructions for the <br /> stakeout are attached and are available in our office. <br /> DRY SOIL CONDITIONS ARE REQUIRED FOR INSTALLATION(March 1 —October 31).The geographical area in which <br /> the property lies is considered a risk to installation during winter months. Soil moisture conditions generally preclude <br /> construction of the drainfield in the winter months. <br /> Additional Conditions of Site Approval <br /> 1. This site is approved for the type of disposal system described above. Peak sewage flow into the system is limited to a <br /> maximum of 450 gallons per day,with an average sewage flow of not more than 225 gallons per day. This is normally <br /> sufficient to serve a residence with 4(four)bedrooms. Premature failure of the treatment system may occur if either of <br /> these flow quantities is exceeded. If,for some reason,you expect your water use may exceed these flows, it may be <br /> CALL BEFORE YOU DIG...ITS THE LAW <br /> ATTENTION:Oregon law requires you to follow rules adopted by the Oregon Utility Notification Center. Those rules are set forth by Oregon Administration Rules. You may obtain <br /> copies of the rules by calling the center.(Note:The telephone number for the Oregon Utility Notification Center is 1-800-332-2344.) <br /> 7/10/19:11:35:04AM Page 4 of 6 ONS_OnsiteEvaluation_pr <br />