My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8628112
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
19-XXXXXX
>
8628112
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/22/2019 9:00:43 AM
Creation date
5/21/2019 9:27:41 AM
Metadata
Fields
Template:
Permits
Permit Address
14535 SPENNER RD SE
Permit City
STAYTON
Permit Number
555-19-003243-AUTH
Parcel Number
091W02A 00200
Permit Type
Authorization
Permit Doc Type
Permit Document
Status
Ready to Film
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Oregon Department of Environmental Quality <br /> • Dosing tank capacity (gallons) <br /> • Tank volume determined by: Check all that apply,add comments below as needed <br /> 0 Permit Records 0 Measured 0 Stamped on Tank 0 Other <br /> • Dosing tank material <br /> • Dosing tank appears to be watertight and in good condition DYes ONo <br /> • Dosing tank lid is intact [Wes ONo <br /> • Electrical components are sealed and watertight DYes ONo <br /> • Pump/siphon is functional 0Yes ONo <br /> • Type of Pump ODemand dose Dime dose <br /> • Pump control mechanism is functional(floats,pressure transducer)DYes ONo <br /> • There is a high water alarm DYes ['No <br /> • The high water alarm(audible and visual)is working DYes ONo ['Not Applicable <br /> • Type of screen <br /> • Screen is clean and free of debris Dyes ['No-Screen cleaned for this evaluation DYes [QNo <br /> • Scum/sludge present in Dosing tank ['Yes QNo <br /> • Scum layer (inches) Sludge layer (inches) <br /> • Additional Comments: <br /> 5. Soil absorption system <br /> The soil absorption system is a set of trenches that receives effluent from the septic tank and <br /> filters the effluent before it enters the groundwater. <br /> • The septic system has a soil absorption system*tes ONo ['Unknown <br /> • Was the soil absorption system part of the evaluation?IglYes QNo ['See note below <br /> If the soil absorption system was not evaluated,please explain below(for example unable to <br /> locate,client did not authorize this part of the evaluation): <br /> • Absorption distribution lEqual ['Serial ['Pressure ['Equal via pressure <br /> • Absorption lines construction material: <br /> 54 Gravel and pipe ['Chamber Tile 0 Polystyrene foam and pipe 0Other Jrt }i4 al it At-5 are <br /> • Absorption distribution unit(s): Ddropbox['hydrosplitter( equal distribution bo)71k. 'w' lilt es, <br /> • <br /> IN- Intact 0 Damaged 0 N/A &"th 7 re` I d pi pc, <br /> • Absorption distribution unit(s)are free of debris or solids N Yes QNo 0 N/A <br /> Page 4 of 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.