Orenco® Technical Data Sheet
<br /> Components m
<br /> 7i�ww.awww��*® ■■�+
<br /> 1. Inlet !� _ �:� i� II
<br /> 2. Recirc/blend chamber 1 ',1 ' nnn;n �i�1, �+
<br /> 3. Recirc transfer line NI
<br /> 1
<br /> O I
<br /> 4. Recirc pumping system O = Hi ill
<br /> 5. Manifold and spin nozzles Ol Ii.II I I
<br /> 6. Treatment media1IIIIII
<br /> ® c I
<br /> 7. Tank baffle 111 i.,-.�
<br /> 8. Recirc return valve
<br /> ! "'
<br /> O EI O
<br /> 9. Recirc/filtrate chamber
<br /> 10.Divider wall 111
<br /> 11.Orenco AXUV ultraviolet disinfection unit
<br /> 12.Disinfection/discharge chamber AdvanTexAX20-RTUV side view(pump discharge model shown)
<br /> 13.Discharge pumping system
<br /> 14.Outlet �
<br /> O► I '( f
<br /> pe
<br /> 15.External splice box idis , ,®
<br /> vs ral 41D —
<br /> 16.Passive air vent TO
<br /> a.
<br /> 17.Control panel(not shown) ili O 9 <} 1
<br /> 1 in rqfit_ O ��LD 1 2 r
<br /> 18.Biotube®Effluent Filter*(in septic tank,not shown) i i
<br /> re",,,,,, r
<br /> Specifications = • 1® , , , r
<br /> Nominal Dimensions* / , , I , I
<br /> Length,in.(mm) 102(2591)
<br /> Width,in.(mm) 62(1575) AdvanTexAX20-RTUV top view(pump discharge model shown)
<br /> Height,in.(mm) 72(1829)
<br /> Footprint,ft2(m2) 44(4.11) Power cord
<br /> Footprint,ft2(m2)(after installation) 20(1.86) Cord grip
<br /> Lid insulation value R-6(RSI-1.1) [^ Vented lamp handle
<br /> Dry Weight,lb(kg) ate--` -
<br /> Gravity discharge model 908(412) 3-in.(80-mm)quick- y Outlet
<br /> disconnect coupling - _I
<br /> Pump discharge model 948(430)
<br /> UV Unit Performance*
<br /> Typical contact chamber UV 270,000 RWs/cm2 at 1 gpm(0.06 I./sec) Inlet
<br /> dose(65%transmittance 55,000µWs/cm2 at 5 gpm(0.32 L/sec)
<br /> 20%lamp degradation) 28,000 tWs/cm2 at 10 gpm(0.63 Usec) Contact chamber
<br /> Minimum target dose 30,000-38,000 .tWs/cm2.
<br /> Lamp 31 in.(787 mm),92 VAC,50 or 60 Hz,425 mA,
<br /> 38 W;254 nm INC intensity at 1m is 125 lAW/cm2 Teflon®sleeve
<br /> Power cord 600V,18/2 UL Type TC,25 ft(7.62 m)length
<br /> Cord plug UL listed four-pin connector,lampholder,electric UV lamp
<br /> discharge,1000 V or less
<br /> Ballast 120V,AC,50 or 60 Hz,located in UL-listed Flow-through spacer
<br /> Orenco®control panel
<br /> " Not for individual sale in the state of Georgia.
<br /> t Nominal values provided.See AdvanTex®Treatment System drawings for exact dimensions. Orenco AXUV Disinfection Unit,(cutaway view)
<br /> # For additional info and specs,see"Orencdd AXUV Disinfection Unit"(NTD-UV-OSI-2).
<br /> NTD-ATX-AXRT-3 Orenco Systems°Inc.,814 Airway Ave.,Sutherlin,OR 97479 USA • 800-348-9843•541-459-4449•www.orenco.com
<br /> Rev.1.5,©01/16
<br /> Page 2 of 2