Laserfiche WebLink
Septic Authorization 555-19-000917-AUTH Page 2 of 2 <br /> '*a7 tem e neer r a' rf- <br /> .��u� '�:�`'�...�..''� .,.,. �..;�...,"-��"��� ..�;�.a'�,.��`.� .,,.,,.�,;�. .�'��,z�.✓;;a�E,�,....��3u,� ,�� ,��a„? <br /> Conditions of Approval: <br /> Existing system information: <br /> The Marion County has no records regarding the installation of the septic system serving this property. <br /> The system was located on January 21,2019 by Rays Septic Tank Service, revealing approximately 238 linear feet of line. The <br /> tank was also pumped. The pumper noted a 1000 gallon tank and no signs of failure. <br /> A tank installed for the proposed hardship dwelling under permit 555-19-000917-PRMT. The tank was inspected,passed,and <br /> the permit finaled on April 2,2019. <br /> Flow increase information: <br /> The system does not have an approved design flow but is suitable for a 3-bedroom dwelling. The current application is to add a <br /> 1-bedroom hardship dwelling to the existing system.This change of use will result in an addition of 150 gallons per day and can <br /> be approved under Oregon Administrative Rule(OAR)340-071-0205(4). Please see the signed approved site plans dated April <br /> 3,2019. <br /> DRAINFIELD:Existing. <br /> EFFLUENT SEWER:The effluent sewer is the pipe from the septic tank to the distribution box. The material required is 3034 or <br /> Schedule 40 pipe with 18-gauge minimum green tracer wire or green metallic tape placed along the pipe. The effluent sewer <br /> shall extend at least five(5)feet from the tank. There must be a minimum difference of eight(8)inches between the invert(flow <br /> line)of the septic tank outlet and the invert of the distribution or drop box outlet. In Equal Distribution,there must be six(6) <br /> inches of fall between the septic tank outlet and the distribution box inlet. In Serial Distribution,there must be two(2)inches of <br /> fall between the septic tank outlet and the drop box inlet. <br /> OBSERVE ALL SETBACKS AND SEPARATION DISTANCES: As required by the DEQ rules. The well placement is especially <br /> critical and must be located at least 50-feet from the septic tank. A minimum 5-foot setback is required from the septic tank to a <br /> foundation of a building or other structure. A copy of the DEQ setback requirements is enclosed. <br /> The septic tank must be INSPECTED BY A LICENSED PUMPING SERVICE AT LEAST EVERY TEN(10)YEARS. Per OAR <br /> 340-071-0120(2)(c),the system must be evaluated for solids and pumped if over 35 percent or as needed. Excessive <br /> accumulation of these solid materials in the septic tank will cause the solids to wash out of the tank and into the drainfield. This <br /> will cause irreversible damage to the drainfield and will eventually lead to a system failure <br /> THIS SYSTEM MUST BE INSPECTED AND APPROVED PRIOR TO BACKFILL. When work is complete and ready for <br /> inspection, request an inspection by following the instructions on the accompanying permit document. A twenty four hour water <br /> test is required on all septic tank installation.You may leave a message for the inspector if desired. Be sure the System Record <br /> form with the As-Built drawing is on the job or in our office when the inspection is requested. An inspection should be completed <br /> within seven(7)days. <br /> Note:This Notice does not guarantee satisfactory or continuous operation of the sewage system. Should the system fail, a repair <br /> permit from DEQ is required. <br /> If you disagree with this report,you have the right to apply for an authorization notice denial review.The application for review <br /> must be submitted in writing within 45 days of the report issuance and be accompanied by the review fee in OAR <br /> 340-071-0140(3),Table 9C and any additional information DEQ needs to complete the review. <br /> You may apply for a variance to the onsite wastewater treatment system rules. The variance application must include a copy of <br /> the site evaluation report, plans and specifications for the proposed system,specify the rule(s)to which a variance is being <br /> requested,demonstrate the variance is warranted, and include the variance fee in OAR 340-071-140 Table 9C. A variance may <br /> only be granted if the variance officer determines that strict compliance with a rule is inappropriate or special physical conditions <br /> render strict compliance unreasonable, burdensome or impractical. A senior DEQ variance officer will be assigned the variance <br /> application. <br /> Matthew Puntney Onsite Inspector 4/4/19 <br /> 4/4/19:1:37:37PM Page 2 of 2 ONS_OnsiteAuthorization_pr <br />