8580807
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
18-XXXXXX
>
8580807
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/12/2019 10:10:03 AM
Creation date
4/5/2019 9:48:40 AM
Metadata
Fields
Template:
Permits
Permit Address
3853 RIDGEWAY DR SE
Permit City
TURNER
Permit Number
555-18-004098-AUTH
Parcel Number
092W06C 01700
Permit Type
Authorization
Permit Doc Type
Permit Document
Status
Ready to Film
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
• <br /> Oregon Department of Environmental Quality <br /> * Dosing tank capacity (gallons) <br /> * Tank volume determined by:Cfieck all that apply,acid COmments beloW as needed. <br /> Permit'Records Measured • Stamped on Tank Other <br /> * Dosing tank material <br /> * Dosing tank appears to be watertight and in goodzondition Yes No <br /> * Dosing tank lid is intact Yes No <br /> * Electrical components are sealed and watertight Yes No <br /> * Pump/siphon is functional. Yes No <br /> * Type of Pump Demand dose Time dose <br /> * Pump control mechanism is functional(floats,pressure transducer) Yes <br /> No <br /> * There is a high water alarm Yes No <br /> * The high water alarm(audible and visual)is working Yes No Not Applicable <br /> * Type of screen <br /> * Screen is clean and free of debris Yes No <br /> * Screen cleaned for this evaluation Yes No <br /> "` Scum/sludge present in Dosing tank Yes No <br /> * Scum layer (inches) Sludge layer (inches) <br /> * Additional Comments: <br /> 5. Soil absorption systern <br /> The soil absorption system is a set of trenches that receives effluent from the septic tank and <br /> filters the effluent before it enters the groundwater. <br /> * The septic system has a soil absorption system Yes No X Unknown <br /> * Was the soil absorption system part of the evaluation? ,Yes x No See note below <br /> If the soil absorption system was not evaluated,please explain below(for example unable to locate,client did not <br /> authorize this part of the evaluation): <br /> CUSTOMER DID NOT AUTHORIZE <br /> * Absorption distribution Equal Serial Pressure Equal via pressure <br /> * Absorption lines construction material: <br /> Gravel and pipe Chamber Tile Polystyrene foam and pipe Other <br /> * Absorption distribution unit(s): dropbox hydrosplitter equal distribution box <br /> Intact Damaged N/A <br /> * Absorption distribution unit(s)are free of debris or solids Yes No N/A <br /> Page 4 of 8 <br />