Laserfiche WebLink
i <br /> • <br /> OrencO® i° ?4jai1,fa .fk`d '. W9.7s. 7rkf -- ; <br /> r:�, Air vent(on optional flow modulation plate) <br /> I H <br /> O^ Discharge orifice(on optional flow modulation plate) <br /> I 77-77 <br /> s. <br /> A B C <br /> V • • <br /> f♦ D -►I <br /> Specifications <br /> Model FTS0444-36 / FTS0444-36M FTW0436-28 / FTW0436-28M <br /> FTW0444-36 / FTW0444-36M <br /> A-Vault height,in.(mm) 44.00(1118) 36.00(914) <br /> B-Cartridge height,in.(mm) 36.00(915) 28.00(710) <br /> C-Inlet hole height,*in.(mm) 21.25(540) 19.25(489) <br /> D-Nominal diameter,in.(mm) 4.00(100) 4.00(100) <br /> Number of inlet holes 8 8 <br /> Inlet hole diameter,in.(mm) 1.13(29) 1.13(29) <br /> Number of discharge orifices 1 or 21 1 or 21 <br /> Discharge orifice diameter,in.(mm) . 4.00 or 0.25(100 or 6)t 4.00 or 0.25(100 or 6)t <br /> Discharge coupling diameter,in.(mm) 4.00(100) 4.00(100) <br /> Number of air vents 1 1 <br /> Air vent diameter,flow modulation plate,in.(mm) 0.50(13) 0.50(13) <br /> Filter surface area,t ft2(m2) 5.1 (0.50) 3.9(0.40) <br /> Flow area**ftz(m2) 1.5(0.15) 1.2(0.12) <br /> *Inlet hole height can vary depending on the configuration of the tank.Optimum hole height is 70%of the minimum liquid levet , viwN <br /> t Available on optional flow modulation plate. <br /> #Filter area is defined as the total surface area of all individual Biotubese within the filter cartridge. <br /> **Flow area is defined as the total open area(or area of the mesh openings)of all the individual Biotubes within the filter cartridge. <br /> NTD-FT-FTS-1 Orenco Systems®Inc.,814 Airway Ave.,Sutherlin,OR 97479 USA • 800-348-9843•541-459-4449•www.orenco.com <br /> Rev.1.3,©08/14 <br /> Page 2 of 2 <br />