Laserfiche WebLink
Technical <br /> VeriComm° AXB_ Control Panels Data. Sheet <br /> X11 11t <br /> 1. VeriComm®Remote Telemetry Board B=g3 0 ° 1 mou uom <br /> . 2. Motor-Start Contactors �'W -• ion OnOlii- <br /> Ki] <br /> u L_u (3.. -op 2 <br /> 3. Toggle Switcheso CuISE ;I <br /> 4. Control Circuit Breaker o' - } ' �� Ica 1=° <br /> 5. Pump Circuit Breakers <br /> 6. Fuse. 1. U u r�1 3 <br /> .7. Transformer ( 0 4 <br /> . 8. Audio Alarm <br /> 9. Visual Alarm <br /> 131-113 5 <br /> 10. Panel Enclosure <br /> X11 I <br /> 10 9 8 7 6 <br /> Standard Components <br /> Feature Specifications <br /> 1. VeriComm®Remote Telemetry Unit* ATRTU-100:36/18 VAC(center tap transformer),8 digital inputs,4 analog inputs,4 digital <br /> outputs,0 analog outputs,on-board modem(2400 baud),LED input and output indicators, <br /> 1-year battery backup of data and program settings. <br /> 2. Motor-Start Contactors 120 VAC:16 FLA,1 hp,60 Hz;2.5 million cycles at FLA(10 million at 50%of FLA). <br /> 240 VAC:16 FLA,3 hp,60 Hz;2.5 million cycles at FLA(10 million at 50%of FLA). <br /> 3. Toggle Switches Single-pole switch,automatic On,with spring-loaded,momentary,manual On.20 A,1 hp. <br /> 4. Control Circuit Breaker 10 A,OFF/ON switch.Single-pole 120 VAC,double-pole 240 VAC. DIN rail mounting <br /> with thermal magnetic tripping characteristics. <br /> 5. Pump Circuit Breakers 20 A,OFF/ON switch.Single-pole 120 VAC,double-pole 240 VAC. DIN rail mounting <br /> with thermal magnetic tripping characteristics. <br /> 6. Fuse 120 VAC Primary,36 VCT @ 0.85 A Secondary. <br /> 7. Transformer 250 VAC,1 A. <br /> 8. Audio Alarm 95 dB at 24 in.(610 mm),warble-tone sound. <br /> 9. Visual Alarm 7/8 in.(22 mm)diameter red lens,"Push-to-silence."NEMA 4, 1 W bulb,120 VAC. <br /> 10. Panel Enclosure Measures 15.5.in.high x 13.3 in.wide x 6.7 in.deep(384 mm x 338 mm x 170 mm). <br /> NEMA 4X rated.Constructed of UV-resistant fiberglass;hinges and latch are stainless steel. <br /> Conduit couplings provided. <br /> VCOM-AXB1 120 VAC,3/4 hp,14 A,single-phase,60 Hz. <br /> VCOM-AXB2 • . 240 VAC,2 hp,14 A,single-phase,60 Hz. <br /> Optional Components <br /> Feature Specifications . Product Code Adder <br /> Pump Run Light 7/8 in.(22 mm)diameter green lens.NEMA 4,1 W bulb,120 VAC. PRL <br /> Anticondensation Heater Self-adjusting:radiates additional wattage as temperature drops. HT <br /> Programmable Timer Discharge side timed dosing. PT <br /> UV Disinfection Compatibility UV grounded power circuit and alarm contacts. Pump disable upon UV failure. UV <br /> *See VeriComm®Remote Telemetry Unit(ATD-CP-VCOM-1)and VeriComm®Monitoring System(ATD-WEB-VCOM-1)for more detail. . <br /> ATD-CP-VCOM-7 <br /> Rev.2.5©6/06 <br /> Page2of2 <br />