Laserfiche WebLink
Septic Authorization 555-19-001068-AUTH Page 2 of 2 <br /> Dafk Ssued/ !6/19 P.00,�#0g ,15/2t} you � �� .... � � . <br /> lk urk l c ptson� ` � /FL A 8DRM TOEXIST 2°BDRM RES 4 BORN'TOTAL. OONV BDRM Te <br /> 5 1414 <br /> �� d` kiii*.HSI % <br /> Conditions of Approval: <br /> Existing system information: <br /> Marion County records show the existing septic system serving this property was installed in 2004 under permit number <br /> 04-06194. The system consists of a 1000 gallon concrete tank with 450 lineal feet of rock and pipe drainline with serial <br /> distribution. Design flow is 450 gallons per day,generally adequate for a single family dwelling with up to four(4)bedrooms. A <br /> Certificate of Satisfactory Completion is on file. <br /> The septic tank was most recently pumped by Farmers Septic Co. on February 8,2019. The pumper noted a 1000 gallon tank <br /> and no signs of failure. <br /> A site visit was made to the address on March 4,2019 in response to an application to add three bedrooms to an existing shop, <br /> and convert a bedroom in the existing 2-bedroom home to storage, for a total of 4. The system was partially exposed for <br /> inspection. There were no signs of failure. There is adequate room for a repair system. The existing structures meet all <br /> setbacks to the system. <br /> Flow increase information: <br /> According to the DEQ rules for onsite wastewater treatment systems,the increase in projected daily flow from 3-bedroom single <br /> family residence to a 4-bedroom single family residence meets the criteria listed in OAR 340-071-0205(5)(a)-(d)and is an <br /> allowable increase for this system. This AUTHORIZATION TO increase the number of bedrooms is approved. Please see the <br /> approved signed site plans dated March 5,2019. <br /> THE APPROVED SEPTIC SYSTEM AREA MUST BE PROTECTEDfrom any vehicular traffic including construction vehicles, <br /> livestock and farming activities. Other activities such as logging,excavating or filling,driveway placement or any similar activities <br /> may also damage the soil in the area and adversely affect the septic system approval. The areas of the initial septic system and <br /> the future repair system must both be protected. <br /> The septic tank should be pumped and inspectedby a licensed septic tank pumping service approximately every five(5) <br /> years. The septic tank is a reservoir for the solid materials in the sewage waste stream. Excessive accumulation of these solid <br /> materials in the septic tank will cause the solids to wash out of the tank and into the drainfield. This will cause irreversible <br /> damage to the drainfield and will eventually lead to a system failure. <br /> Note:This Notice does not guarantee satisfactory or continuous operation of the sewage system. Should the system fail,a repair <br /> permit from DEQ is required. <br /> If you disagree with this report,you have the right to apply for an authorization notice denial review.The application for review <br /> must be submitted in writing within 45 days of the report issuance and be accompanied by the review fee in OAR <br /> 340-071-0140(3),Table 9C and any additional information DEQ needs to complete the review. <br /> You may apply for a variance to the onsite wastewater treatment system rules. The variance application must include a copy of <br /> the site evaluation report, plans and specifications for the proposed system,specify the rule(s)to which a variance is being <br /> requested, demonstrate the variance is warranted, and include the variance fee in OAR 340-071-140 Table 9C. A variance may <br /> only be granted if the variance officer determines that strict compliance with a rule is inappropriate or special physical conditions <br /> render strict compliance unreasonable,burdensome or impractical. A senior DEQ variance officer will be assigned the variance <br /> application. <br /> Matthew Puntney Onsite Inspector 3/6/19 <br /> 3/6/19:8:11:54AM Page 2 of 2 ONS_OnsiteAuthorizationpr <br />