Laserfiche WebLink
ALIGN SANITARY TEE TO <br />ALLOW FULL EXPOSURE <br />AS CLOSE TO EDGE OF <br />OPENING AS POSSIBLE <br />AND DINING HALL <br />00.5" <br />26" I.D. ACCESS PORT WITH <br />30" RISER STARTER CAST -IN-PLACE <br />BY TANK MANUFACTURER <br />SEE DETAIL 3, SHEET T4 <br />19" 43„ <br />4" SCH 40 PVC <br />TO SURGE DOSING TANK 86" <br />(SEE SHEET T3) <br />I 26" I.D. ACCESS PORT WITH <br />19" 30" RISER STARTER CAST -IN-PLACE <br />EXTERNAL BY TANK MANUFACTURER <br />SPLICE BOX SEE DETAIL 3, SHEET T4 <br />I <br />PLAN VIEW <br />3FEET <br />SCALE <br />30"o PVC RISER SPLICE BOX <br />AND LID <br />ELECTRICAL <br />CONDUIT TO <br />CONTROL <br />PANEL <br />30"0 ACCESS <br />2I GRATE <br />AND DINING HALL <br />3 <br />2000 GALLON WAITE J SECTION VIEW <br />CONCRETE SEPTIC TANK o 3 FEET <br />MODIFIED AS SHOWN S® <br />30"0 PVC RISER <br />AND LID WITH GASKET <br />AND VENT <br />CUSTOM BIOTUBE <br />EFFLUENT FILTER <br />SEE DETAIL 1, SHEET T4 <br />- S.S. BAND CLAMP <br />4" CAST -A -SEAL <br />4" SCH 40 PVC <br />—� TO SURGE DOSING TANK <br />(SEE SHEET T3) <br />SEEP RING <br />* Item numbers are provided as a courtesy. Since specific numbers and supplementary codes <br />can change, supplier is to compare this information to the drawings and independently verity. <br />Call designer if there are any Inconsistencies or questions. <br />Labels and General Information <br />Orenco Equipment <br />Symbol <br />Name <br />Filtration Septic Tank <br />Quantity <br />Item * <br />Description/Comments <br />2 <br />RR3029 <br />Access Riser, 30" Diameter (Inlet) <br />1 <br />RR3029 + XS <br />Access Riser, 30" Diameter with XS (Outlet) <br />2 <br />FLD30G <br />Fiberglass Lid, 30" with Gasket and 4 Bolt Pattern <br />1 <br />RG30 <br />30" Diameter Access Grate (Inlet) <br />1 <br />SBEX1 <br />External Splice Box with 1 Cord Grip (High Level Alarm) <br />1 <br />MF1P-Y-18FTL <br />Float Assembly with 1 Float (Effluent Filter) <br />1 <br />FT 0854-36A <br />Biotube Effluent Filter with Alarm Float Stem Bracket <br />4 <br />MA320 <br />2 -Part Epoxy for Securing Riser to Tank Adapter <br />1 <br />ADH100 <br />Caulking for Final Seal Between Riser and Tank Adapter <br />* Item numbers are provided as a courtesy. Since specific numbers and supplementary codes <br />can change, supplier is to compare this information to the drawings and independently verity. <br />Call designer if there are any Inconsistencies or questions. <br />GENERAL NOTES: <br />1. CLASSIFICATION FOR ELECTRICAL EQUIPMENT: <br />UNCLASSIFIED (NFPA 820, TABLE 3, NO. 19 - <br />INTERMEDIATE OR FINAL PUMPING STATIONS). <br />2. RECOMMENDED WIRING AS CLASS I, DIVISION 2. <br />3. MAXIMUM BURIAL DEPTH OF THIS TANK IS 48" <br />'REUSE OF DOCUMENTS: THIS DOCUMENT AND THE IDEAS AND DESIGN INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE IS THE PROPERTY OF CASCADE EARTH SCIENCES AND IS NOT TO BE USED, WHOLE OR IN PART WITHOUT THE WRITTEN AUTHORIZATION OF CASCADE EARTH SCIENCES <br />CP <br />Certified Professional <br />Soil Scientist <br />BRIAN T. RABE <br />15239 Exp. <br />Registered Wastewater Specialist <br />No. EH -W448430 Exp. <br />REV if DESCRIPTION BY DATE DES. ITL BTR Filtration Septic Tank SHEET <br />Yspenia Russian Orthodox Church DRG. BY Boo CASCADE EARTH SCIENCES <br />(2,000 Gal. Waite Concrete Products) <br />13495urnnMonitor Rd. A Valmont Industries Company T2 <br />Woodburn, oE11/10/2015 Cs078-63 z <br />JOB No 2016240208 cres <br />FOR NATIONAL OFFICE LOCATIONS Sewage System Treatment Alteration <br />Labels and General Information <br />Symbol <br />Name <br />Distance From Tank Floor (in.) <br />Distance From Exterior Tank Top (In.) <br />InSTt <br />Inlet Sanitary Tee (Top of Pipe) <br />75.5 <br />8 <br />Inlnv <br />Inlet Invert <br />70.5 <br />13 <br />HLA <br />High Level Alarm <br />70.5 <br />3 serf sc �P�rLy <br />Outlnv <br />Outlet Invert/Minimum Liquid Level <br />68.5 <br />15 )41C.'4 e2 fv oar <br />InSTb <br />Inlet Sanitary Tee (Bottom of Pipe) <br />53.5 <br />30 or- sc14-1 M4yr-2 <br />BInH <br />Biotube Inlet Holes <br />52.5 <br />31 <br />Riser Height (in.) <br />Inlet Pipe Size (In.) <br />Outlet Pipe Size (in.) <br />Tank Location <br />29 <br />4 <br />4 <br />New Tank Assembly East of Restroom Building <br />GENERAL NOTES: <br />1. CLASSIFICATION FOR ELECTRICAL EQUIPMENT: <br />UNCLASSIFIED (NFPA 820, TABLE 3, NO. 19 - <br />INTERMEDIATE OR FINAL PUMPING STATIONS). <br />2. RECOMMENDED WIRING AS CLASS I, DIVISION 2. <br />3. MAXIMUM BURIAL DEPTH OF THIS TANK IS 48" <br />'REUSE OF DOCUMENTS: THIS DOCUMENT AND THE IDEAS AND DESIGN INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE IS THE PROPERTY OF CASCADE EARTH SCIENCES AND IS NOT TO BE USED, WHOLE OR IN PART WITHOUT THE WRITTEN AUTHORIZATION OF CASCADE EARTH SCIENCES <br />CP <br />Certified Professional <br />Soil Scientist <br />BRIAN T. RABE <br />15239 Exp. <br />Registered Wastewater Specialist <br />No. EH -W448430 Exp. <br />REV if DESCRIPTION BY DATE DES. ITL BTR Filtration Septic Tank SHEET <br />Yspenia Russian Orthodox Church DRG. BY Boo CASCADE EARTH SCIENCES <br />(2,000 Gal. Waite Concrete Products) <br />13495urnnMonitor Rd. A Valmont Industries Company T2 <br />Woodburn, oE11/10/2015 Cs078-63 z <br />JOB No 2016240208 cres <br />FOR NATIONAL OFFICE LOCATIONS Sewage System Treatment Alteration <br />