Laserfiche WebLink
METAL TRACER TAPE <br />OR WIRE <br />10' <br />WATER LINE <br />JOINT OR FITTING <br />10' 1 <br />JOINT OR <br />SEWER <br />LINE <br />NOTE: IF THE SEPARATION DISTANCE BETWEEN THE PIPES <br />CANNOT BE ACHIEVED, A SECTION OF THE WATER LINE <br />SHALL BE REPLACED WITH A 20' LENGTH OF SCH 40 <br />PVC, CENTERED ON THE INTERSECTION AS SHOWN. THE <br />PIPES SHALL BE BEDDED SO THAT THEY DO NOT TOUCH <br />AT THE INTERSECTION. <br />EFFLUENT SEWER / WATER <br />1 LINE CROSSING — SECTION <br />0 2 FEET <br />SCALE <br />12" MIN <br />EFFLUENT — <br />SEWER LINE <br />0 2 FEET <br />SCALE <br />N <br />NEW SURFACE <br />OR SURFACE <br />RESTORATION <br />TRENCH BA( <br />ABOVE PIPE <br />"B" MIN. SELECTED SOIL <br />BACKFILL OR J" MINUS - <br />:RUSHED ROCK (COMPACTED) <br />PIPE OUTSIDE DIAMETER - <br />PIPE BEDDING MATERIAL "A" <br />(UNDISTURBED ROCK -FREE - <br />EFFLUENT SEWER / WATER SOIL OR COMPACTED SAND) <br />LINE CROSSING — PLAN TRENCH STABILIZATION <br />0 2 FEET WHERE REQD <br />I <br />SCALE <br />2x6 ROOF <br />SUPPORT <br />2x4 BRACE <br />MOUNT CONTROL <br />PANEL TO CROSS <br />BRACING <br />N z CONDUIT FROM <br />\ POWER SUPPLY <br />01 WATER. LINE ALL LUMBER TO <br />I(X_ PRESSURE TREA <br />'oN S,P oc- 6-o>Cy <br />COV WITH <br />-6" RO TNG FELT <br />AC/A ASPHALT <br />PLYWOOD <br />_2x4 CROSS <br />60" BRACE <br />4x4 PRESSURE <br />TREATED POST <br />CONCRETE <br />INSTALLED UNDER INSTALLED UNDER <br />ASPHALT OR CONCRETE GRASS <br />FROST -FREE HOSE <br />BI8, HEAVY DUTY <br />HOSE HANGER AND <br />50' OF HEAVY <br />DUTY HOSE <br />9 <br />PIPE ZONE <br />MIN WIDTH <br />PIPE OID C <br />UTILITYTYPE <br />MINIMUM DEPTH <br />NATIVE SOIL <br />OF COVER "D" <br />BACKFILL <br />(30" WHERE CROSSING <br />MARKING <br />UNDER ROADS OR <br />TAPE AS <br />PARKING LOTS) <br />SPECIFIED <br />TI <br />A� �c <br />1 6" <br />1 12" <br />PIPE ZONE <br />MIN WIDTH <br />PIPE OID C <br />UTILITYTYPE <br />A <br />B <br />C <br />D <br />GRAVITY SEWER <br />2" <br />4" <br />12" <br />18" <br />PRESSURE SEWER <br />1 2" <br />1 6" <br />1 12" <br />24" <br />TRANSPORT PIPING — SECTION <br />(FORCE MAIN, BUILDING SEWER, <br />0 2 FEET <br />SCALE <br />3'-9" <br />�3'-3"-{ <br />30" _ <br />`" � CONTROL PANEL DETAIL <br />NOT TO SCALE <br />M <br />CONTROL/ <br />ALARM PANEL <br />0 0 <br />o CONDUIT SEAL <br />0 <br />'REUSE OF DOCUMENTS: THIS DOCUMENT AND THE IDEAS AND DESIGN INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE IS THE PROPERTY OF CASCADE EARTH SCIENCES AND IS NOT TO BE USED, WHOLE OR IN PART WITHOUT THE WRITTEN AUTHORIZATION OF CASCADE EARTH SCIENCES <br />CONDUIT FROM <br />POWER SUPPLY <br />Certified Professional <br />Sail Scientist <br />BRIAN T. RABE <br />15239 Exp. <br />Registered Woslewoter Specielisi <br />No. EH -W448430 Exp. <br />REV DESCRIPTION BY DATE I DES. B1' BTR SHEET <br />Yspenia Russian Orthodox Church DRG. BY BDD CASCADE EARTH SCIENCES Miscellaneous Details <br />13495 Woodburn Monitor Rd. CHK. BY --- A Valmont Industries Company M 1 <br />Woodburn, Oregon DATE 11/16/2016 CALL 1-800-728-8322 Sewage System Treatment Alteration <br />JOB N,,201640208 FOR NATIONAL OFFICE LOCATIONS g y <br />