My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Financial- Century West (File1-2)
>
CS_Courthouse Square
>
Financial- Century West (File1-2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/19/2012 3:26:45 PM
Creation date
8/19/2011 11:36:24 AM
Metadata
Fields
Template:
Building
RecordID
10146
Title
Financial- Century West (File1-2)
Company
Marion County
BLDG Date
1/1/1999
Building
Courthouse Square
BLDG Document Type
Finance
Project ID
CS9601 Courthouse Square Research
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
769
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
• s <br />observations (petroleum staining, depth to groundwater, and odor) and the PID results will be used <br />to select a maximum of two soil samples from each boring for laboratory analyses. If there is no field <br />evidence of contamination in a particular investigative boring, only one soil sample will be collected <br />near the water table for analysis. <br />Soil samples will be labeled to reflect the sample location, depth, and time of collection, placed into <br />a cooler with ice, and transported under chain-of-custody conditions to an analytical laboratory <br />certified by the Department of Environmental Quality (DEQ). All soil samples will be analyzed for <br />total petroleum hydrocarbons - gasoline range (TPH-Gx) and total petroleum hydrocarbons - diesel <br />range (TPH-Dx). The six soil samples with the highest petroleum hydrocarbon concentrations will <br />be further analyzed for benzene, toluene, ethylbenzene, and xylenes (BTE~ and polynuclear aromatic <br />hydrocarbons (PAHs). In addition, if gasoline is detected, the two soil samples with the highest TPH- <br />Gx concentrations will be analyzed for EDB/EDC and total lead. The detection limits for all analyses <br />will be less than the RBCA Tier I cleanup levels. The maximum number of analyses to be completed <br />on the soil samples, including one field duplicate, is summarized in the following table: <br />SUIL SAMPLIl~G <br />~,nialysis I Number ot <br /> Sam !es* <br />TPH-Gx 13 <br />TPH-Dx 13 <br />PAHs 7 <br />BTEX 7 <br />EDB/EDC 2 <br />Total Lead 2 <br />*Number of samples assumes that a <br />maximum of 6 investigative borings will be <br />completed to delineate the extent of <br />contamination. <br />The drill augers and sampling equipment will be decontaminated between borings. The soil cuttings <br />will be placed in labeled and secure 55-gallon drums. <br />Task 3 Reporting <br />Century West will prepare a report upon completion of the field activities. The report will include <br />a summary of the subsurface investigation, analytical results, conclusions, and recommendations. <br />Copies of the chain-of-custody documentation, laboratory data sheets, and boring logs will be <br />included in the report as appendices. <br />
The URL can be used to link to this page
Your browser does not support the video tag.