My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Interim Architect Agreement/Contract
>
CS_Courthouse Square
>
Interim Architect Agreement/Contract
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/19/2012 11:47:23 AM
Creation date
8/2/2011 11:15:47 AM
Metadata
Fields
Template:
Building
RecordID
10061
Title
Interim Architect Agreement/Contract
Company
Arbuckle/Costic
BLDG Date
1/1/1999
Building
Courthouse Square
BLDG Document Type
Contracts - Agreements
Project ID
CS9801 Courthouse Square Construction
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
346
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
January 25, 1999 <br />ARBUCKLE COSTIC ARCHITECTS, INC. <br />363 State Street <br />Salem, Oregon 97301 <br />Phone: (503) 581-4114 <br />Fa~ (503) 581-3655 <br />COURTHOUSE SQUARE <br />555 Court Street NE <br />Saiem, O~gon <br />Projed No. 9828 <br />ADDENDUM NO. 2: <br />TO: ALL BIDDERS OF RECORD <br />This addendum fams a part of the Contrad Doa~meMs and modifies the Drawings and Specifications dated <br />Deoember 30,1998, as noted below. Acknowiedge receipt of this addendum in the space provided on the <br />Form of Proposal. Failune to do so may subject Bidder to disqualification. <br />Soecifications <br />1. Section 00123~ Instrudions to Bidders: <br />a. Add Paragraph 3.1.H as foliows: <br />'Provide camplete infortnadon on qppendices -A', -g•~ 'C' and 'D' to the Form of Proposal, <br />showing lump sum values for each line item. Total up lump sum values in each group for <br />Base Bid and/or for Aftemate No. 3 or Altemate Na 11 and indude in r+espective lump sum, <br />a Fonn of Proposal. Where quantities and un'its are shown i~ the ~efe~+enoed columns, <br />divide the lump sum by the quantity shown to show applicable 'Unit Prices' by line ftem. <br />Quarrtities shown are estimated oniy. Contractor must verify quantities in preparing lump <br />sum elemerrt costs. <br />2. Sedion 00131, Form of Proposal: - <br />a. Delete this sedion in its errtirety and ~eplace with the new Section 00131, FoRn of Proposal, <br />appended to this addendum. <br />3. Sedion 01520, Environmerrtal Practices: <br />a. Add Paragraph 1.6.C as follows: <br />`Emission Rate Standar+ds: As a minimum, all material shall meet the emission rate <br />standarcls set forth below. <br />1. Fortnaidehyde Em'~ssion Rate Standarcl: The produd emissio~ rate measured in <br />mg/m2 h~ will nat iesu~ in an indoor air conoe~ration level of foRnaidehyde goeater <br />than 0.05 ppm at the anticipated loading (mz/m' within the building) within 30 days <br />of installation. . <br />2. Totai Volatile Organic (VOC) Emission Rate StandaRi: The produd emission rate <br />in mg/m2 hr. which wili not result in an indoor ai~ concerrtration level greater than <br />0.5 mg/m~ of totai volatile or~ganic compounds at the arrticipated loading (mZ/m3 <br />within the building) within 30 days of installation. <br />
The URL can be used to link to this page
Your browser does not support the video tag.