Laserfiche WebLink
DATE/TIME <br />TYPE <br />OCCUPANCY <br />CONST TYPE <br />UGB: SITE: <br /> <br /> BUILDING PERMIT <br />11/24/99 15:07 PERMIT NO <br />Commercial addition/alteration STATUS <br />S-3 ISSUED <br />V-N TO EXPIRE <br /> PAGE <br /> <br />99-07949 <br />ISSUED <br />11/24/1999 <br />05/22/2000 <br /> 2 <br /> <br />REQUIRED SETBACKS: Front: <br /> <br />PLAN REVIEW COMMENTS AND CONDITIONS <br /> <br /> Left: Right: Rear: <br /> <br />Special: <br /> <br /> 1. CALL BEFORE YOU DIG .... IT'S THE LAW. <br /> ATTENTION: Oregon law requires you to follow rules adopted <br /> by the Oregon Utility Notification Center, Those rules are <br /> set forth in OAR 952-001-0010 through OAR 952-001-0090. You <br /> may obtain copies of the rules by calling the center. <br /> (Note: The telephone number for the Oregon Utility Notifica- <br /> tion Center is (503) 232-1987), <br /> 2. THIS PLAN REVIEW WAS COMPLETED BY T COLEMAN ON 11/23/99, <br /> 3, Approval of submitted plans is not an approval of omissions <br /> or oversights by this office or of noncompliance with any <br /> applicable regulations of local government. <br />4. This is a plan review covering the alterations to the above <br /> existing building. This review is based on the regulations <br /> of the Oregon State Structural Specialty Code ('97 UBC) <br /> 1998 Edition. <br /> ADDING 4 INTERIOR ROOMS AND STORAGE LOFT TO PREVIOUSLY <br /> CONSTRUCTED POLE FRAME BUILDING. <br /> 60 FT, X 40 FT. : 2.400 SQ. FT (ORIGINAL BUILDING) <br /> 5, STAIRWAY CONSTRUCTION: <br /> THE TOP OF HANDRAILS AND HANDRAIL EXTENSIONS SHALL NOT BE <br /> PLACED LESS THAN 34 INCHES NOR MORE THAN 38 INCHES ABOVE THE <br /> NOSING OF THE TREADS, THE HANDGRIP PORTION OF HANDRAILS <br /> SHALL NOT BE LESS THAN 1,25 INCHES NOR MORE THAN 2 INCHES <br /> IN CROSS SECTIONAL DIMENSIONS OR THE SHAPE SHALL PROVIDE <br /> AN EQUIVALENT GRIPPING SURFACE. <br /> THE 2X4 HANDRAILS DO NOT PROVIDE A GRIPABLE SURFACE, <br /> 6, EVERY STAIRWAY SHALL HAVE A HEADROOM CLEARANCE OF NOT LESS <br /> THAN 6 FEET 8 INCHES. <br /> 7, Portable fire extinguishers shall be provided and installed <br /> as required by applicable standards and as directed by the <br /> authority having jurisdiction. <br /> <br />8. ~oilet room floors shall have a smooth, hard, nonabsorbent <br /> surface such as portland cement, concrete, ceramic tile or <br /> other approved material which extends upward onto the walls <br /> at least 5 inches. <br />9, Walls within 2 feet of the front and sides of urinals and <br /> water closets shall have a smooth, hard, nonabsorbent <br /> surface such as portland cement, concrete, ceramic tile or <br /> other smooth, hard nonabsorbent surface to a height of 4 <br /> feet, and except for structural elements, the materials <br /> used in such walls shall be of a type which is not adverse- <br /> ly affected by moisture. <br /> <br />10. insulation and vapor barriers when exposed are to have a <br /> flame spread not to exceed 25, <br />11. The mechanical and electrical plans are not covered by this <br /> review, Mechanical and electrical systems are required to <br /> be in compliance with applicable codes. <br />12. The live loads for which each floor has been designed shall <br /> have such design live loads conspicuously posted by the <br /> owner in that part of each story which they apply, using <br /> durable metal signs. The occupant of the building shall be <br /> responsible for keeping the actual load below the allowable <br /> limits, <br /> STORAGE LOFT 40 POUNDS PER SQUARE FOOT (?) <br /> <br /> <br />