Laserfiche WebLink
DATE/TIME <br />TYPE <br />OCCUPANCY <br />CONST TYPE <br />UGB: SITE: <br /> <br /> BUILDING PERMIT <br />11/26/99 08:35 PERMIT NO <br />Resident. addition/alteration STATUS <br />R-3 ISSUED <br />V-N TO EXPIRE <br /> PAGE <br /> <br />99-06112 <br />ISSUED <br />11/26/1999 <br />05/24/2000 <br /> 2 <br /> <br /> PLAN REVIEW COMMENTS AND CONDITIONS <br /> <br />REQUIRED SETBACKS: Front: 20 Left: 20 Right: 20 Rear: 20 Special: <br /> <br /> 1, CALL BEFORE YOU DIG .... IT'S THE LAW. <br /> ATTENTION: Oregon law requires you to follow rules adopted <br /> by the Oregon Utility Notification Center. Those rules are <br /> set forth in OAR 952-001-0010 through OAR 952-001-0090, You <br /> may obtain copies of the rules by calling the center, <br /> (Note: The telephone number for the Oregon Utility Notifica- <br /> tion Center is (503) 232-1987). <br /> 2. THIS PLAN REVIEW WAS COMPLETED BY 'W.JACKSON ON 10/26/1999. <br /> 3. Approval of submitted plans is not an approval of omissions <br /> or oversights by this office or of noncompliance with any <br /> applicable regulations of local government. <br /> 4. Additional kitchens in a dwelling unit are permitted <br /> provided all kitchens in the dwelling unit are used by only <br /> one family. <br /> <br /> * CALL FOR AN INSPECTION * <br /> * WHEN THIS PERMIT * <br /> * IS ISSUED * <br /> <br /> 6. SMOKE DETECTORS / ALTERATIONS. When alterations, repairs or <br /> additions requiring a permit occur, or when sleeping rooms <br /> are added or created, the entire building shall be provided <br /> with smoke detectors located as required for new dwellings; <br /> the smoke detectors shall be interconnected and hard wired. <br /> EXCEPTION: Detectors shall not be required to be inter- <br /> connected and hard wired where the alterations, repairs, or <br /> additions do not result in the exposure of electrical wiring <br /> by the removal of interior wall and ceiling finishes, <br /> [Sec. 316.1.1] <br /> 7. SMOKE DETECTORS shall be installed in each sleeping room. <br /> outside of each separate sleeping aFea in the in~ediate <br /> vicinity of the bedrooms and on each additional story of the <br /> dwelling including basements. All detectors located outside <br /> sleeping rooms shall be interconnected such that the <br /> actuation of one alarm will actuate these alarms in the <br /> individual unit and shall provide an alarm which will be <br /> audible in all sleeping areas. Smoke detectors shall be <br /> 110 volt with batter back-up. [Sec. 316.1] <br /> 8, ACCEPTABILITY. This plan review covers the addition to and/ <br /> or alteration of an existing structure. This review is not <br /> intended to prohibit the building inspector from requesting <br /> an evaluation of the acceptability of existing structural <br /> members that may appear to be unsafe. Existing construction <br /> not specifically detailed in the submitted plans and struc- <br /> tural calculations is beyond the scope of this review. <br /> 9. TRUSS DESZGN Roof trusses are required to be be designed by <br /> an Oregon registered Engineer or Architect. For trusses <br /> manufactured by an approved fabrication plant, have the <br /> design and layout drawings available at the construction <br /> site for the framing inspection. All jobsite cutting or <br /> modifications of the roof trusses shall be clearly shown in <br /> the engineer's design calculations and drawings. <br />10, ATTIC VENTS. Provide screened attic vents with a net free <br /> area of 1/150 of the attic area (or 1/300 if between 50 of <br /> 80 percent of required area is ventilators in the upper <br /> portion of the attic and located at least 3 feet above eave <br /> or cornice vents). As an alternative, install a 1mil vapor <br /> barrier on the warm side of the ceiling, [Sec. 806.2] <br />11. EVERY SLEEPING ROOM shall have at least one openable window <br /> or exterior door approved for emergency egress or rescue. <br /> The window sill height shall not be more than 44 inches <br /> above the floor. The minimum net clear opening is 5.7 square <br /> feet. The minimum net clear opening height shall be 22 <br /> inches. The minimum net clear opening width shall be 20 <br /> inches. Exception: Grade floor windows may have a minimum <br /> <br /> <br />