Laserfiche WebLink
DATE/TIME <br />TYPE <br />OCCUPANCY <br />CONST TYPE <br />UGB: OT SITE: <br /> <br /> BUILDING PERMIT <br /> 06/14/00 16:29 PERMIT NO <br /> Resident, addition/alteration STATUS <br /> R-3 ISSUED <br /> V-N TO EXPIRE <br /> PAGE <br /> area of 1/150 of the attic area (or 1/300 if between 50 of <br /> 80 percent of required area is ventilators in the upper <br /> portion of the attic and located at least 3 feet above eave <br /> or cornice vents), As an alternative, install a i mil vapor <br /> barrier on the warm side of the ceiling, [Sec, 806.2] <br />15, LANDINGS. A minimum 2 foot x 3 foot landing shall be <br /> required on each side of an egress door. The floor or <br /> landing shall not be more than i and 1/2 inches lower than <br /> the top of the threshold. Exceptions: (1) At the top of a <br /> flight of stairs, provided the door does not swing over the <br /> stairs, (2) The landing at the exterior doorway shall not <br /> be more than 8 1/4 inches below the top of the threshold, <br /> [Sec, 312.1] <br /> <br />99-05971 <br />ISSUED <br />0671472000 <br />12/11/2000 <br /> 3 <br /> <br /> <br />