Laserfiche WebLink
· DATE/TIME <br /> TYPE <br /> OCCUPANCY <br /> CONST TYPE <br /> UGB: DT SITE: <br /> <br /> BUILDING PERMIT <br />06/09/99 15:29 PERMIT NO <br />Resqdential accessory struct STATUS <br />U-1 ISSUED <br />V-N TO EXPIRE <br /> PAGE <br /> <br />99-04246 <br />ISSUED <br />06/09/1999 <br />12/06/1999 <br /> 2 <br /> <br />PLAN REVIEW COMMENTS AND CONDITIONS <br /> <br />REQUIRED SETBACKS: Front: 20 Left: 5 Right: 5 Rear: 15 Specqal: <br /> <br />1. CALL BEFORE YOU DIG .... IT'S THE LAW, <br /> A~ENTION: Oregon law requires you to follow rules adopted <br /> by the Oregon Utility Notification Center, Those rules are <br /> set forth in OAR 952~001~0010 through OAR 952-001-0090. You <br /> may obtain copqes of the rules by calling the center. <br /> (Note: The telephone number for the Oregon Utility Notifica- <br /> tion Center is (503) 232-1987). <br />2. THIS PLAN REVIEW WAS COMPLETED BY S, FREILINGER ON 6/7/99. <br />3. Approval of submitted plans qs not an approval of omissions <br /> or oversights by this office or of noncompliance with any <br /> applicable regulations of local government. <br />4. ORIGINAL DESIGN. The original design as submitted for revie <br /> w is denied and does not comply with the minimum code requir <br /> ements and the applicable snow load for the roof design for <br /> the Detroit area. <br />5, RAFTERS, Provide a minimum of 2x10 DF #2 rafters at 16" on <br /> center as the size of the origqnal design are overspanned <br /> for the snow load at the elevation in Detroit. <br />6. POSTS. Provide a minimum of 4x6 pressure treated posts. <br />7. WOOD COLUMNS shall be approved wood of natural decay <br /> resistance or approved pressure treated wood, Exception: <br /> Post or columns not subject to the weather and supported by <br /> piers projecting 2 inches above the floor or finish grade <br /> and separated therefrom by an approved moisture barrier. <br /> [Sec, 322.1,4] <br />8. POST EMBEDIMENT. The 4x6 P,T. posts shall be a minimum of <br /> 4 feet embedded in the ground qn a 15" diameter hole. After <br /> the post is installed the hole shall be filled with concrete <br /> or compacted gravel. <br />9, GROUND SNOW LOAD, The ground snow load in the Detroit area <br /> is 73 PSF. <br /> <br /> <br />