My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
DWELL - 1596493
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
99-XXXXX
>
DWELL - 1596493
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/22/2013 3:50:01 PM
Creation date
2/15/2005 1:11:09 PM
Metadata
Fields
Template:
Permits
Permit Address
140 4TH ST W
Permit City
Detroit
Permit Number
555-99-03426
Parcel Number
105E02AD06400
Permit Type
DWELL
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
DATE/TIME <br />TYPE <br />OCCUPANCY <br />CONST TYPE <br />UGB: DT SITE: <br /> <br /> DWELLING PERMIT <br />07/02/99 16:16 PERMIT NO <br />New Single Family Dwelling STATUS <br />R-3 ISSUED <br />V-N TO EXPIRE <br /> PAGE <br /> <br />99-02426 <br />ISSUED <br />07/02/1999 <br />12/29/1999 <br />2 <br /> <br /> PLAN REVIEW COMMENTS AND CONDITIONS <br /> <br />REQUIRED SETBACKS: Front: 20 Left~ 5 Right: 5 Rear: 15 Special: <br /> <br /> 1. Approval of submitted plans is not an approval of omissions <br /> or oversights by this office or of noncompliance with any <br /> applicable regulations of local government, <br /> 2. CALL BEFORE YOU DIG .... IT'S THE LAW. <br /> A~ENTIDN~ Oregon law requires you to follow rules adopted <br /> by the Oregon Utility Notification Center. Those rules are <br /> set forth in OAR 952-001-0010 through OAR 952-001-0090, You <br /> may obtain copies of the rules by calling the center, <br /> (Note: The telephone number for the Oregon Utility Notifica- <br /> tion Center is (503) 232-1987). <br />3. THIS PLAN REVIEW was completed by W.JACKOSN ON 6/29/1999. <br /> This plan was reviewed under the 1996 Edition of the State <br /> of Oregon One and Two Family Dwelling Specialty Code. <br />4~ ENGINEERING CALCULATIONS PREPARED BY: <br /> <br /> Rebai Tamerhoulet <br /> Certification No,: 16953PE <br /> S & T Consulting Engineers <br /> 6635 Skyline Road South <br /> Salem. OR 97306 <br /> PH: (503) 588-5907 <br /> <br /> Mr. Tamerhoulet has made design assumptions for vertical and <br /> horizontal loads based on his engineering knowledge and <br /> experience as a registered professional engineer. <br />6. THE TJI FLOOR joist system shall be installed in accordance <br /> with its listing and the manufacturer's installation in- <br /> structions, Please have the installation instructions <br /> available during the framing inspection~ <br />6. SAFETY GLAZING / LARGE PANE, The following shall be con- <br /> sidered a specific hazardous location for the purposes of <br /> glazing. Glazing in an individual fixed or operable pane <br /> that meets all of the following conditions: <br /> 1, Exposed area of an individual pane greater than 9 sq. ft <br /> 2, Bottom edge less than 18 inches above the floor~ <br /> 3. Top edge greater than 36 inches above the floor. <br />7, SAFETY GLAZING / LARGE PANE.(Continued, see above condition) <br /> 4. One or more walking surfaces within 36 inches horizon- <br /> tally of the glazing. Exception: In lieu of safety glazing <br /> this specific glazed panel may be protected with a pro- <br /> tective bar installed on the accessble side(s) of the <br /> glazing 36 inches (plus or minus 2 inches) above the floor. <br /> The bar shall be capable of withstanding a horizontal load <br /> of 50 pounds per linear foot without contacting the glass <br /> and be a minimum of i 1/2 inches in height. <br />8. EVERY SLEEPING ROOM shall have at least one openable window <br /> or exterior door approved for emergency egress or rescue. <br /> The window sill height shall not be more than 44 inches <br /> above the floor. The minimum net clear opening is 5.7 square <br /> feet. The minimum net clear opening height shall be 22 <br /> inches, The minimum net clear opening width shall be 20 <br /> inches, Exception: Grade floor windows may have a minimum <br /> net clear opening of 5 square feet, [Sec, 310.2. 310.2.1] <br />9, SMOKE DETECTORS shall be installed in each sleeping room. <br /> outside of each separate sleeping area in the immediate <br /> vicinity of the bedrooms and on each additional story of the <br /> dwelling including basements. All detectors located outside <br /> sleeping rooms shall be interconnected such that the <br /> actuation of one alarm will actuate these alarms in the <br /> individual unit and shall provide an alarm which will be <br /> audible in all sleeping areas. Smoke detectors shall be <br /> 110 volt with batter back-up. [Sec, 216.1] <br />10. STAIRWAYS shall not be less than 36 inches in clear width at <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.