Laserfiche WebLink
DATE/TIME <br />TYPE <br />OCCUPA}ICY <br />CONST ~PE <br />UGB: SITE: <br /> <br /> DWEELING PERMIT <br />12/16/98 15:47 PERMIT NO <br />New Single Family Dwelling STATUS <br />R-2 ISSUED <br />V-N TO EXPIRE <br /> PAGE <br /> <br />90-10151 <br />ISSUED <br />12/16/1998 <br />06/14/1999 <br />2 <br /> <br />PLAN REVIEW COMMENTS AND CONDITIONS <br /> <br />REQUIRED SETBACKS: Front: 20 Left: 8 Right: 52 Rear: 8 Special: <br /> <br />RIGHT SB: 52.6 <br /> <br /> 1, C~qLL BEFORE YOU DIG .... IT'S THE LAW. <br /> A~ENTION: Oregon law requires you to follow rules adopted <br /> by the Oregon Utility Notification Center, Those rules are <br /> set forth in OAR 952-001-0010 through OAR 952-001-0090. You <br /> may obtain copies of the rules by calling the center. <br /> (Note: The telephone number for the Oregon Utility Notifica- <br /> tion Center is (502) 232-1987). <br /> 2, THIS PLAN REVIEW was completed by J TRUSSELL ON 12-16-98. <br /> This plan was reviewed under the 1996 Edition of the State <br /> of Oregon One and Two Family Dwelling Specialty Code. <br /> 2, Approval of submitted plans is not an approval ofomissions <br /> or oversights by this office or of noncompliance with any <br /> applicable regulations of local government. <br /> 4. GROUNDING ELECTRODES, When concrete reinforcing bars are <br /> installed in concrete footings, the following requirements <br /> shall be met to provide for a grounding electrode system: <br /> 1, Uncoated No. 4 reinforcing bar installed not less <br /> 20 feet in length encased with a minimum of 2 inches of <br /> concrete. <br /> 2. An uncoated No. 4 reinforcing bar stubbed up at least <br /> 12 inches above the floor plate line and tightly attached to <br /> the reinforcing bar located in the footing. The spliced lap <br /> of the staubbed up bar to the footing shall be a minimum of <br /> 12 inches. (See Section 4108.1.2) [Sec. 402.4] <br /> 5, MAXIMUM FILL HEIGHT. The foundation/basement wall was re- <br /> viewed assuming a maximum 4 feet of unbalanced fill or less. <br /> If the actual height of fill is mere than 4 feet. then an <br /> addendum to this plan review shall be made by the permit <br /> holder, by submitting to this office revised foundation/ <br /> basement wall plans that are an engineered design (with cal- <br /> culations) showing the true fill height or that meet the <br /> requirements of Table 404.1:1b in the cede. SUBMIT BEFORE <br /> CONSTRUCTION COMMENCES. <br /> 6. WATERPROOFING REQUIRED, Foundation walls enclosing <br /> habitable or storage space shall be waterproofed. <br /> [Sec. 406,2] <br /> 7, ENG. This structure uses an Engineered Design to meet the <br /> lateral wall bracing requirements of the code. Insure that <br /> all detailed construction requirements shown on the plans <br /> are followed, Engineer design by Tim Coovert. <br /> 8. TRUSS DESIGN. Roof trusses are required to be be designed by <br /> an Oregon registered Engineer or Architect. For trusses <br /> manufactured by an approved fabrication plant, have the <br /> design and layout drawings available at the construction <br /> site for the framing inspection. All jobsite cutting or <br /> modifications of the roof trusses shall be clearly shown in <br /> the engineer's design calculations and drawings, <br />9, THE GAP~kGE shall be separated from the dwelling and its <br /> attic area by means of 1/2 inch gypsum board applied to the <br /> garage side of the wall, Where the separation is a floor- <br /> ceiling assembly, the structure supporting the separation <br /> shall be protected by 1/2 inch gypsum board or equivalent, <br /> The door oetw~en the garage and residence shall be equipped <br /> with solid wood doors not less than i 2/8 inches in thick- <br /> ness or 20-minute fire-rated, or equivalent. <br /> [Sec. 209,1, 209.2] <br />10, EVERY SLEEPING ROOM shall have at least one openable window <br /> or exterior door approved for emergency egress or rescue. <br /> The window sill height shall not be mere than 44 inches <br /> above the floor. The minimum net clear opening is 5.7 square <br /> feet. The minimum net clear opening height shall be 22 <br /> inches. The minimum net clear opening width shall be 20 <br /> inches. Exception: Grade floor windows may have a minimum <br /> <br /> <br />