My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BUILD - 1531248
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
98-XXXXX
>
BUILD - 1531248
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/21/2013 3:16:13 PM
Creation date
12/29/2004 8:43:50 AM
Metadata
Fields
Template:
Permits
Permit Address
20508 CASE RD NE
Permit City
Aurora
Permit Number
555-98-10077
Parcel Number
042W13 02200
Permit Type
BUILD
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
BUILDING PERMIT <br />DATE/TIME 12/07/98 12:00 <br />TYPE Resident, addition/alteration <br />OCCUPANCY R-3 <br />CONST TYPE V-N <br />UGB: SITE: FD <br /> <br />PERMIT NO <br />STATUS <br />ISSUED <br />TO EXPIRE <br />PAGE <br /> <br />98-10077 <br />ISSUED <br />12/07/1998 <br />06/05/1999 <br /> 2 <br /> <br />PLAN REVIEW COMMENTS AND CONDITIONS <br /> <br />REQUIRED SETBACKS: Front: 20 Left: 20 Right: 20 Rear: 20 Special: <br /> <br />1. CALL BEFORE YOU DIG .... IT'S THE LAW. <br /> ATTENTION: Oregon law requires you to follow rules adopted <br /> by the Oregon Utility Notification Center. Those rules are <br /> set forth in OAR 952-001-0010 through OAR 952-001-0090. You <br /> may obtain copies of the rules by calling the center, <br /> (Note: The telephone number for the Oregon Utility Notifica- <br /> tion Center is (503) 232-1987). <br />2, THIS PLAN REVIEW WAS COMPLETED BY M. JONES ON 12/04/98. <br />2, Approval of submitted plans is not an approval of omissions <br /> or oversights by this office or of noncompliance with any <br /> applicable regulations of local government, <br />4. ACCEPTABILITY. This plan review covers the addition to and/ <br /> or alteration of an existing structure. This review is not <br /> intended to prohibit the building inspector from requesting <br /> an evaluation of the acceptability of existing structural <br /> members that may appear to be unsafe. Existing construction <br /> not specifically detailed in the submitted plans and struc- <br /> tural calculations is beyond the scope of this review, <br />5, BP, ABP. This structure uses a combination of Brace Wall <br /> Panels (BP) and Alternate Braced Wall Panels (ABP) to meet <br /> the cede requirements for lateral wall bracing. Insure that <br /> all BP's are located as indicated on the plans. <br />6. SAFETY GLAZING / AT DOOR. The following shall be considered <br /> specific hazardous locations for the purposes of glazing: <br /> Glazing, in an individual fixed or operable panel <br /> adjacent to a door where the nearest vertical edge is <br /> within a 24 inch arc of the door in a closed position <br /> and whose bottom edge is less than 60 inches above <br /> the floor or walking surface, Exception: Safety <br /> glazing is not required when there is an intervening <br /> wall or other permanent barrier between the door and <br /> the glazing. <br />7. THE GAPJ~GE shall be separated from the dwelling and its <br /> attic area by means of 1/2 inch gypsum board applied to the <br /> garage side of the wall. Where the separation is a floor- <br /> ceiling assembly, the structure supporting the separation <br /> shall be protected by I/2 inch gypsum board or equivalent, <br /> The door between the garage and residence shall be equipped <br /> with solid wood doors not less than I 3/8 inches in thick- <br /> ness or 20-minute fire-rated, or equivalent. <br /> [Sec. 309.1, 309.2] <br />8. EVERY SLEEPING ROOM shall have at least one openable window <br /> or exterior door approved for emergency egress or rescue, <br /> The window sill height shall not be more than 44 inches <br /> above the floor, The minimum net clear opening is 5,7 square <br /> feet, The minimum net clear opening height shall be 22 <br /> inches. The minimum net clear opening width shall be 20 <br /> inches. Exception: Grade floor windows may have a minimum <br /> net clear opening of 5 square feet. [Sec. 210.2. 310.2.1] <br />9. SMOKE DETECTORS / ALTERATIONS, When alterations, repairs or <br /> additions requiring a permit occur, or when sleeping rooms <br /> are added or created, the entire building shall be provided <br /> with smoke detectors located as required for new dwellings: <br /> the smoke detectors shall be interconnected and hard wired, <br /> EXCEPTION: Detectors shall not be required to be inter- <br /> connected and hard wired where the alterations, repairs, or <br /> additions do not result in the exposure of electrical wiring <br /> by the removal of interior wall and ceiling finishes. <br /> [Sec. 316.1.1] <br />10, SMOKE DETECTORS shall be installed in each sleeping room. <br /> outside of each separate sleeping area in the immediate <br /> vicinity of the bedrooms and on each additional story of the <br /> dwelling including basements. All detectors located outside <br /> sleeping rooms shall be interconnected such that the <br /> actuation of one alarm will actuate these alarms in the <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.