DATE/TIME 09/21/98 16:36 <br />TYPE Foundation Only <br />OCCUPANCY R-2 <br />CONST TYPE V-N <br />UGB: SITE: FD <br /> <br />BUILDING PERMIT <br /> <br />PERMIT NO <br />STATUS <br />ISSUED <br />TO EXPIRE <br />PAGE <br /> <br />98-07992 <br />ISSUED <br />09/21/1998 <br />02/20/1999 <br /> 2 <br /> <br />PLAN REVIEW COMMENTS AND CONDITIONS <br /> <br />REQUIRED SETBACKS: Front: Left: Right: Rear: Special: <br /> <br /> 1. CALL BEFORE YOU DIG .... IT'S THE LAW. <br /> ATTENTION: Oregon law requires you to follow rules adopted <br /> by the Oregon Utility Notification Center. Those rules are <br /> set forth in OAR 952-001-0010 through OAR 952 001-0090. You <br /> may obtain copies of the rules by calling the center. <br /> (Note: The telephone number for the Oregon Utility Notifica- <br /> tion Center is (503) 232-1987). <br />2. THIS PLAN REVIEW WAS COMPLETED BY DWALTERS ON 9/17/98, <br /> 1996 CODE, <br />3, Approval of submitted plans is not an approval of omissions <br /> or oversights by this office or of noncompliance with any <br /> applicable regulations of local government, <br />4, ACCEPTABILITY. This plan review covers the addition to and/ <br /> or alteration of an existing structure, This review is not <br /> intended to prohibit the building inspector from requesting <br /> an evaluation of the acceptability of existing structural <br /> members that may appear to be unsafe. Existing construction <br /> not specifically detailed in the submitted plans and struc- <br /> tural calculations is beyond the scope of this review. <br />5. INSURE THAT THERE ARE HOLDONNS INSTALLED THRU THE NEW 2X <br /> GREENPLATE INTO THE BLOCK AT NO MORE THAN 6' O.C, FOR 1/2" X <br /> 10 "J" BOLTS AND AS PER THE INSTALLATION INSTRUCTIONS FOR <br /> MANUFACTURED HOLDOWNS, <br />6. THERE IS NO DETAIL SHOWN ON HOW THE NEW 2X GREENPLATE WILL <br /> BE ATTACHED TO THE EXISTING 4X6, ATTACH THE 2 MEMBERS TOGET <br /> HER IN SUCH A WAY AS TO TRANSFER ALL GRAVITY AND LATEP~qL LOA <br /> DS, ASK YOUR INSPECTOR FOR SUGGESTIONS. <br />7. SMOKE DETECTORS / ALTERATIONS. When alterations, repairs or <br /> additions requiring a permit occur, or when sleeping rooms <br /> are added or created, the entire building shall be provided <br /> with smoke detectors located as required for new dwellings: <br /> the smoke detectors shall be interconnected and hard wired. <br /> EXCEPTION: Detectors shall not be required to be inter- <br /> connected and hard wired where the alterations, repairs, or <br /> additions do not result in the exposure of electrical wiring <br /> by the removal of interior wall and ceiling finishes. <br /> [Sec. 316.1.1] <br />8. SMOKE DETECTORS shall be installed in each sleeping room, <br /> outside of each separate sleeping area in the immediate <br /> vicinity of the bedrooms and on each additional story of the <br /> dwelling including basements. All detectors located outside <br /> sleeping rooms shall be interconnected such that the <br /> actuation of one alarm will actuate these alarms in the <br /> individual unit and shall provide an alarm which will be <br /> audible in all sleeping areas. Smoke detectors shall be <br /> 110 volt with batter back-up. [Sec. $16.1] <br /> <br /> <br />