Laserfiche WebLink
DATE/TIME <br />~PE <br />OCCUPANCY <br />CONST TYPE <br />UGB: SITE: <br /> <br /> BUILDING PERMIT <br />09/22/98 09:39 PERMIT NO <br />Commercial addition/alteration STATUS <br />S-5 ISSUED <br />II-N TO EXPIRE <br /> PAGE <br /> <br />98-07466 <br />ISSUED <br />09/22/1998 <br />02/21/1999 <br /> 2 <br /> <br />PlAN REVIEW CO~)ENTS AND CONDITIONS <br /> <br />REQUIRED SETBACKS: Front: left: Right: Rear: Special: <br /> <br /> 1, C~d_L BEFORE YOU DIG .... IT'S THE LAW, <br /> A~ENTION: Oregon law requires you to follow rules adopted <br /> by the Oregon Utility Notification Center. Those rules are <br /> set forth in OAR 952-001-0010 through OAR 952-001-0090, You <br /> may obtain copies of the rules by calling the center. <br /> (Note: The telephone number for the Oregon Utility Notifica- <br /> tion Center is (503) 232-1987). <br />2, THIS PLAN REVIEW WAS COMPLETED BY M, JONES ON 09/17/98. <br />3. Approval of submitted plans is not an approval of omissions <br /> or oversights by this office or of noncompliance with any <br /> applicable regulations of local government. <br />4. This is a plan review covering the alterations to the above <br /> existing building. This review is based on the regulations <br /> of the Oregon State Structural Specialty Code ('94 UBC) <br /> 1996 Edition, <br /> This is a TENANT IMPROVEMENT for the construction of a <br /> 6 foot by 8 foot restroom only for HANGAR #18. <br />5, TOILET ROOM FLOORS, (OSSC Sec 807.1.1) <br /> Toilet room floors shall have a smooth, hard nonabsorbent <br /> surface such as portland cement, concrete, ceramic tile or <br /> other approved material which extends upward onto the walls <br /> 5 inches. <br />6. TOILET ROOM WALLS. (OSSC Sec 807.1.2) <br /> Walls within 2 feet of the front and sides of urinals and <br /> water closets shall have a smooth, hard nonabsorbent surface <br /> of portland cement, concrete, ceramic tile or other approved <br /> smooth, hard nonabsorbent surface to a height of 4 feet and <br /> except for structural elements, the materials used in such <br /> walls shall be of a type which is not adversely affected by <br /> moisture. See Section 2512 for other limitations, <br /> EXCEPTION #2, Toilet rooms which are not accessible to the <br /> public and which have not more than one water <br /> closet. <br />7. TOILET ROOM VENTILATION. (OSSC Sec 1202.2.5) <br />Rooms containing a water closet shall be provided with a <br />fully openable exterior window with an area not less than 2 <br />square feet in area: or a vertical duct not less than 100 <br />square inches in area for the first water closet, with an <br />additional 50 square inches of area for each additional <br />water closet, or a mechanically operated exhaust system <br />capable of exhausting 50 cubic feet of air per minute for <br />each water closet installed in the toilet room. <br />8. TOILET ROOM VENTILATION, cont'd. <br />Such mechanically operated exhaust systems shall be <br />connected directly to the outside, and the point of <br />discharge shall be at least 2 feet from any opening which <br />allows air entry into occupied portions of the building. <br /> <br /> <br />