Laserfiche WebLink
DATE/TIME <br />TYPE <br />OCCUPANCY <br />CONST TYPE <br />UGB: AM SITE: <br /> <br /> BUILDING PERMIT <br />04/12/99 16:32 PERMIT NO <br />Commercial addition/alteration STATUS <br />E-2 ISSUED <br />V-N TO EXPIRE <br /> PAGE <br /> <br />98-06804 <br />ISSUED <br />04/12/1999 <br />10/09/1999 <br /> 2 <br /> <br />PLAN REVIEW COMMENTS AND CONDITIONS <br /> <br />REQUIRED SETBACKS: Front: Left: Right: Rear: Special: <br /> <br /> 1. CALL BEFORE YOU DIG .... IT'S THE LAW. <br /> ATTENTION: Oregon law requires you to follow rules adopted <br /> by the Oregon Utility Notification Center. Those rules are <br /> set forth in OAR 952-001-0010 through OAR 952-001-0090, You <br /> may obtain copies of the rules by calling the center. <br /> (Note: The telephone number for the Oregon Utility Notifica- <br /> tion Center is (502) 222-1987). <br /> 2. THIS PLAN REVIEW W~S COMPLETED BY M. JONES ON 04/12/99. <br /> 3. Approval of submitted plans is not an approval of omissions <br /> or oversights by this office or of noncompliance with any <br /> applicable regulations of local government. <br /> 4. This project may be subject to the architectural standards <br /> of the Americans with Disabilities Act of 1990 (ADA). <br /> Issuance of a building permit does not certify compliance <br /> with this Federal Statute, Copies of the guidelines and <br /> information concerning the ADA may be obtained from the <br /> Architectural and Transportation Barriers Compliance Board, <br /> 1-202-653-7834 (Voce/TDD) or 1-800-USA-ABLE, Failure to <br /> comply with the ADA may result in Federal fines and <br /> penalties. <br /> 5, local Fire Districts may have additional requirements that <br /> affect this project, You are advised to contact the Fire <br /> Oistrict before you proceed, <br /> 6. This is a Plan Review covering the construction of the <br /> above addition to the existing building. This review is <br /> for compliance with the provisions of the Oregon State <br /> Structural Specialty Code ('97 UBC) 1998 Edition. <br /> 7. BUILDING CODE SUMMARY: <br /> Occupancy Classification: E-2 (addition) / A-3 (existing) <br /> Type of Construction: V-N <br /> Basic Allowable Area: 6,000 sq ft <br /> Existing area: 6,595 sq ft <br /> Proposed addition: 1,625 sq ft <br /> Total: 8,220 sq ft <br /> Maximum Number of Stories: I * BUILDING YARDS: <br /> Proposed: 1 * North: 10' to <br /> Maximum Building Height: 40 ft * South: 20' to Main St. <br /> Proposed: 22 ft * East: 26' to 1st St. <br /> · Nest: 13' to 2nd St, <br /> 8. ALLOWABLE AREA INCREASES. (OSSC Sec 505) <br /> Separation on three sides. Where public ways or yards more <br /> than 20 feet in width extend along and adjoin three sides of <br /> the building, floor areas may be increased at a rate of <br /> 2-t/2 percent for each foot by which the minimum width <br /> exceeds 20 feet, but the increase shall not exceed 100 <br /> percent. <br /> 60 foot public streets on three sides plus distance from <br /> exterior wall to property line adjoining public street <br /> will give 100 percent increase. <br /> Basic allowable of 6,000 sq ft w/increase equals 12,000 sq <br /> ft which is greater than 8.220 sq ft, <br /> 9, SPECIAL HAZARDS. (OSSC Sec 305.8) <br /> Class I, II or III-A liquids shall not be placed, stored or <br /> used in Group. E Occupancies. except in approved quantities <br /> as necessary in laboratories and classrooms and for <br /> operation and maintenance as set forth in the fire code. <br />lO, FIRE ALARM SYSTEM. (OSSC Sec 305.9) <br /> An approved fire alarm system shall be provided for Group E <br /> Occupancies with an occupant load exceeding 50 persons. <br /> In Group Occupancies provided with an automatic sprinkler <br /> or detection system, the operation of such system shall <br /> automatically activate the school fire alarm system, which <br /> shall include an alarm mounted on the exterior building, <br /> See Chapter lO for smoke-detection requirements. <br /> For installation requirements, see the Fire Code. <br /> <br /> <br />