My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BUILD - 1521654
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
98-XXXXX
>
BUILD - 1521654
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/19/2013 2:46:45 PM
Creation date
12/13/2004 7:33:12 AM
Metadata
Fields
Template:
Permits
Permit Address
22995 SCOTT LN NE; 10328 CHAMPOEG RD NE
Permit City
Aurora
Permit Number
555-98-06012
Parcel Number
041W06D 01100
Permit Type
BUILD
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
DATE/TIME <br />TYPE <br />OCCUPANCY <br />CONST TYPE <br />UGB: SITE: <br /> <br /> BUILDING PERMIT <br />07/29/98 15:10 PERMIT NO <br />Residential accessory struct STATUS <br />S-1 ISSUED <br />V-N TO EXPIRE <br /> AG PAGE <br /> <br />98-06012 <br />ISSUED <br />07/29/1998 <br />01/25/1999 <br /> 2 <br /> <br />PLAN REVIEW COMMENTS AND CONDITIONS <br /> <br />REQUIRED SETBACKS: Front: 20 Left: 20 Right: 20 Rear: 20 Special: <br /> <br /> 1, CALL BEFORE YOU DIG .... IT'S THE LAW, <br /> A~ENTION: Oregon law requires you to follow rules adopted <br /> by the Oregon Utility Notification Center, Those rules are <br /> set forth in OAR 952-001-0010 through OAR 952-001-0090, You <br /> may obtain copies of the rules by calling the center, <br /> (Note: The telephone number for the Oregon Utility Notifica- <br /> tion Center is (503) 232-1987), <br />2, THIS PLAN REVIEW WAS COMPLETED BY M, JONES ON 07/28/98. <br />3, Approval of submitted plans is not an approval of omissions <br /> or oversights by this office or of noncompliance with any <br /> applicable regulations of local government, <br />4. Approved for private non-commercial use only. <br />5. SPECIAL HAZARDS, <br /> (OSSC Sec 211,8) <br /> Storage and use of flammable and combustible liquids shall <br /> be in accordance with the Fire Code, <br /> <br /> 6, STAIRWAY WIDTH. (OSSC Sec 1006.2) <br /> Stairways serving an occupant load of 49 or less shall not <br /> be less than 36 in width, <br /> Handrails may project into the required width a distance of <br /> 3-1/2 inches from each side of a stairway. Stringers and <br /> other projections such as trim and similar decorative <br /> features may project into the required width 1-1/2 inches on <br /> each side, <br /> 7. RISE and RUN, (OSSC Sec 1006,3) <br /> The rise of steps shall not be less than 4 inches or greater <br /> than 7 inches. <br /> The run shall not be less than 11 inches as measured <br /> horizontally between the vertical planes of the furthermost <br /> ~rojection of adjacent treads, <br /> he largest tread run shall not exceed the smallest by more <br /> than 3/8 inch, The greatest riser height shall not exceed <br /> the smallest by more than 3/8 inch, <br /> EXCEPTION: l, Private steps & stairways serving an occupant <br /> load of less than lO may be constructed with <br /> an 8 inch max rise & 9 inch minimum run. <br /> 8. HANDP~qILS, (OSSC Sec 1006,9) <br /> Stairways shall have handrails on each side, <br /> EXCEPTION: <br /> 1, Stairways less than 44 inches in width may have one <br /> handrail. <br /> The top of handrails shall be placed not less than 34 inches <br /> or more than 28 inches above the nosing of treads and land- <br /> ings, Handrails shall be continuous the full length oF the <br /> stairs. The handgrip portion of handrails shall not be less <br /> than L-I/4 inches nor more than 2 inches in cross-sectional <br /> di~nsion or the shape shall provide an equivalent gripping <br /> surface, <br /> 9. GURADRAILS ON STAIRS. (OSSC Sec lO06,10 & 509) <br /> The top of guradrails shall not be less than 34 inches or <br /> more than 38 inches, exclusive of their landings. <br /> Open guradrails shall have intermediate rails or ornamental <br /> pattern such that a sphere 4 inches in diameter cannot pass <br /> through. <br />lO, INTERIOR STAIRWAYS. (OSSC Sec 1006.11) <br /> Enclosed usable space under stairs shall be protected on the <br /> enclosed side as required for one-hour fire-resistive <br /> construction. <br />il, HEADROOM, (OSSC Sec 1006,15) <br /> Every stairway shall have a headroom clearance of not less <br /> than 6 feet 8 inches. <br /> Such clearances shall be measured vertically from a plane <br /> parallel and tangent to the stairway tread nosings to the <br /> soffit above at all points, <br />12. GUARDRAILS, (OSSC Sec 509) <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.