My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BUILD - 1521487
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
98-XXXXX
>
BUILD - 1521487
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/19/2013 2:48:37 PM
Creation date
12/13/2004 7:31:24 AM
Metadata
Fields
Template:
Permits
Permit Address
12334 EHLEN RD NE
Permit City
Aurora
Permit Number
555-98-06053
Parcel Number
041W09DD00600
Permit Type
BUILD
Permit Doc Type
Permit Document
Document Relationships
Frontage Plans - Approved
(Permits)
Path:
\Public Works - Permits\Engineering\Land Development\Construction Site Plans\EHLEN RD NE\12334 EHLEN RD NE\LDEP Plans
Frontage Plans - As-Builts
(Permits)
Path:
\Public Works - Permits\Engineering\Land Development\Construction Site Plans\EHLEN RD NE\12334 EHLEN RD NE\LDEP Plans
Memorandum of Agreement
(Permits)
Path:
\Public Works - Permits\Engineering\Land Development\Construction Site Plans\EHLEN RD NE\12334 EHLEN RD NE
Prelim Redlines
(Permits)
Path:
\Public Works - Permits\Engineering\Land Development\Construction Site Plans\EHLEN RD NE\12334 EHLEN RD NE\LDEP Plans
Prop Share Est
(Permits)
Path:
\Public Works - Permits\Engineering\Land Development\Construction Site Plans\EHLEN RD NE\12334 EHLEN RD NE\Traffic
Redlines 2
(Permits)
Path:
\Public Works - Permits\Engineering\Land Development\Construction Site Plans\EHLEN RD NE\12334 EHLEN RD NE\LDEP Plans
Redlines 3
(Permits)
Path:
\Public Works - Permits\Engineering\Land Development\Construction Site Plans\EHLEN RD NE\12334 EHLEN RD NE\LDEP Plans
ROW Ded
(Permits)
Path:
\Public Works - Permits\Engineering\Land Development\Construction Site Plans\EHLEN RD NE\12334 EHLEN RD NE
Traffic Letter 13-0117
(Permits)
Path:
\Public Works - Permits\Engineering\Land Development\Construction Site Plans\EHLEN RD NE\12334 EHLEN RD NE\Traffic
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
DATE/TIME <br />TYPE <br />OCCUPANCY <br />CONSTI~fPE <br />UGB: SITE: <br /> <br />BUILDING PERMIT <br /> <br />09/25/98 08:58 PERMIT NO <br />New Commercial STATUS <br />S-1 ISSUED <br />V-N TO EXPIRE <br /> PAGE <br /> <br />98-06053 <br />ISSUED <br />09/25/1998 <br />03/24/1999 <br /> 2 <br /> <br />PLAN REVIEW COMMENTS AND CONDITIONS <br /> <br />REQUIRED SETBACKS: Front: Left: Right: Rear: <br /> OK AS PER SITE PLAN <br /> <br />Special: <br /> <br /> 1, CALL BEFORE YOU DIG .... IT'S THE LAW, <br />A1-FENTION: Oregon law requires you to follow rules adopted <br />by the Oregon Utility Notification Center, Those rules are <br />set forth in OAR 952-001-0010 through OAR 952-001-0090. You <br />may obtain copies of the rules by calling the center. <br />(Note: The telephone number for the Oregon Utility Notifica- <br />tion Center is (502) 222-1987). <br />2. THIS PLAN REVIEW WAS COMPLETED BY M, JONES ON 07/20/98. <br />2, Approval of submitted plans is not an approval of omissions <br />or oversights by this office or of noncompliance with any <br />applicable regulations of local government. <br />4, This is a Plan Review covering the construction of the <br />above indicated new building. Plans have been reviewed for <br />compliance with the provisions of the Oregon State <br />Structural Specialty Code ('94 UBC) 1996 Edition. <br />5, LOCATION ON PROPERTY. (OSSC Sec 503) <br /> Exterior walls shall have fire resistance and opening <br /> protection as set forth in TABLE 5-A and in accordance with <br /> such additional provisions as are set forth in chapter 6. <br /> Distances shall be measured at right angles from the propert <br /> y line. The following requirements are based on a S-1 <br /> Occupancy of Type V-N construction: <br /> Exterior Walls: One-hour less than 20 feet <br /> Openings: Not permitted less than 5 feet and protected <br /> less than 10 feet with a minimum fire assembly <br /> having at least a three-fourths-hour fire <br /> protection rating. <br />6, LOCATION ON PROPERTY, cont'd, <br /> For the purposes of determining the required wall and open- <br /> ing protection and roof-covering requirements, buildings on <br /> the same property shall be assumed to have a property line <br /> between them. <br /> When a new building is to be erected on the same property as <br /> an existing building, the location of the assumed property <br /> line with relation to the existing building shall be such <br /> that the exterior wall and opening protection of the exist- <br /> ing building meet the criteria as set forth in TABLE 5-A and <br /> Chapter 6, <br />7. SPECI~J- HAZARDS. (OSSC Sec 311,8) <br /> Storage and use of flammable and combustible liquids shall <br /> be in accordance with the Fire Code, <br /> Devices generating a glow, spark or flame capable of <br /> igniting flammable vapors shall be installed such that <br /> sources of ignition are at least 18 inches above the floor <br /> of any room in which Class I flammable liquids or flammable <br /> gases are used or stored. <br />$. PLUMBING FIXTURES. (OSSC Sec Appendix Sec 2905) <br />Each building shall be provided with sanitary facilities, <br />including provisions for accessibility in accordance with <br />Chapter 11, <br />EXCEPTION: <br />2, Except in restaurants and dining establishments or where <br />patrons have paid a fee for attendance and will remain <br />in the building for an extended period of time, sanitary <br />fixtures may be located in an adjacent building on the <br />same property, <br />7. Buildings not normally occupied. <br />9. TRUSS DESIGN. <br />The design of the roof trusses was not submitted with the <br />plans and is not include in this plan review. <br />Roof trusses are required to be designed by an Oregon <br />registered Engineer or Architect, For trusses manufactured <br />by an approved fabrication plant, have the truss design and <br />layout drawings available at the construction site for the <br />framing inspection. <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.