My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BUILD - 1521397
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
98-XXXXX
>
BUILD - 1521397
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/19/2013 2:51:00 PM
Creation date
12/13/2004 7:30:32 AM
Metadata
Fields
Template:
Permits
Permit Address
8800 HOLMQUIST RD SE
Permit City
Aumsville
Permit Number
555-98-06143
Parcel Number
081W31C 00500
Permit Type
BUILD
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
DATE/TIME <br />TYPE <br />OCCUPANCY <br />CONST TYPE <br />UGB: SITE: <br /> <br /> BUILDING PERMIT <br />08/07/98 14:50 PERMIT NO <br />Resident. addition/alteration STATUS <br />R-2 ISSUED <br />V-N TO EXPIRE <br /> PAGE <br /> <br />98-06143 <br />ISSUED <br />DB/O7/199B <br />02/02/1999 <br /> 2 <br /> <br />PLAN REVIEW COMMENTS AND CONDITZONS <br /> <br />REQUIRED SETBACKS: Front: Left: 10 Right: Rear: Special: <br /> <br /> 1. CALL BEFORE YOU DIG .... IT'S THE LAW, <br /> AI-FENTION: Oregon law requires you to follow rules adopted <br /> by the Oregon Utility Notification Center, Those rules are <br /> set forth in OAR 952-001-0010 through OAR 952-001-0090, You <br /> may obtain copies of the rules by calling the center. <br /> (Note: The telephone number for the Oregon Utility Notifica- <br /> tion Center is (502) 222-1987). <br />2. THIS PLAN REVIEW WAS COMPLETED BY DWALTERS ON 8/6/98. <br /> 1996 CODE. <br />3, Approval of submitted plans is not an approval of omissions <br /> or oversights by this office or of noncompliance with any <br /> applicable regulations of local government. <br />4. ACCEPTABILITY, This plan review covers the addition to and/ <br /> or alteration of an existing structure. This review is not <br /> intended to prohibit the building inspector from requesting <br /> an evaluation of the acceptability of existing structural <br /> members that may appear to be unsafe. Existing construction <br /> not specifically detailed in the submitted plans and struc- <br /> tural calculations is beyond the scope of this review, <br /> 5. SMOKE DETECTORS / ALTERATIONS. When alterations, repairs or <br /> additions requiring a permit occur, or when sleeping rooms <br /> are added er created, the entire building shall be provided <br /> with smoke detectors located as required for new dwellings: <br /> the smoke detectors shall be interconnected and hard wired. <br /> EXCEPTION: Detectors shall not be required to be inter- <br /> connected and hard wired where the alterations, repairs, or <br /> additions do not result in the exposure Of electrical wiring <br /> by the removal of interior wall and ceiling finishes, <br /> [Sec. 216.1,1] <br />6. VAPOR BARRIER, An approved vapor barrier with joints lapped <br /> not less than 12 inches shall be placed between the concrete <br /> floor slab and the base course or subgrade. Exception: The <br /> vapor barrier may be omitted from detached garages~ utility <br /> buildings and ether unheated accessory structures. <br /> [Sec. 505.2,2] <br />7. BP, This structure uses Brace Wall Panels (BP) to meet the <br /> code requirement for lateral wall bracing. Insure that all <br /> BP's are located as indicated on the plans, <br />8. TRUSS DESIGN. Roof trusses are required to be be designed by <br /> an Oregon registered Engineer or Architect. For trusses <br /> manufactured by an approved fabrication plant, have the <br /> design and layout drawings available at the construction <br /> site for the framing inspection. All jobsite cutting or <br /> modifications of the rooftrusses shall be clearly shown in <br /> the engineer's design calculations and drawings. <br />9. EGRESS / REMODEL. If an existing bedroom Emergency Egress <br /> Window is being removed in the construction of the addition <br /> or remodel, then another egress window or an exterior door <br /> shall be installed in that bedroom. <br />10. ENERGY PATH #1 is based on R-21 wall insulation, R-25 under- <br /> floor insulation, R-30 vaulted ceiling insulation, R-38 flat <br /> ceiling insulation. R-15 below grade wood. concrete or <br /> masonry walls, R-15 slab floor edge insulation, R-8 forced <br /> air duct insulation, 0.40 U-value window class. 0.50 U-value <br /> skylight class, 0,54 U-value main entry door, (with a max- <br /> imum area of 24 square feet) all other exterior doors, in- <br /> cluding the door between the heated drilling and the un- <br /> heated garage, 0.20 U-value. <br />11. SMOKE DETECTORS shall be installed in each sleeping room, <br /> outside of each separate sleeping area in the immediate <br /> vicinity of the bedrooms and on each additional story of the <br /> dwelling including basements. All detectors located outside <br /> sleeping rooms shall be interconnected such that the <br /> actuation of one alarm will actuate these alarms in the <br /> individual unit and shall provide an alarm which will be <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.