Laserfiche WebLink
14. <br /> <br />IS. <br /> <br />FIRESTOPPING shall be provided in the following locatious: <br /> 1) In concealed spaces of stud wails, including furred spaces not to exceed 10 feet horizontally, <br /> and at the ceiling and floor level. <br /> 2) At all interconncclions between concealed vertical and horizontal spaces such as occur at sofli~s, <br /> drop or cove ceJlJn~gs, etc. <br /> 3) In concx.~tied spaces between s~r stringers at thc top and bottom of the run and wall cavities in <br /> U~ wid~ ~ s~-in~e~s; <br /> 4) At opcnin~ around vents, pipes, ducts, chimneys and fireplaces at ceiling and floor level, with <br /> noncombustible materials. <br /> <br />HEATING AND COOLING appliances located in a garage shall be protect~ from impact by automob'fles. <br />Appliaaces that generate a glow, spark or tl~m~ capable of igniting gasoline vapo~ located in a garage shall <br />be i~stalled with burners, burner ignition devices or heating eleme~s and switches at least 18 inches above <br />the floor level. <br /> <br />WATER HEA'FFA~ shall be anchored or strapped to thc building to resist horlzonVa! di~placomcnt d~c to <br />earthquake motion. <br /> <br />TRUSS DESIGN. Roof trmses are required to be designed by an Oregon registered Eatgnecr or Architect. <br />For u'usses manufactured by an approved fabrication plant, have the design and hyout drawings available at <br />the construction site for thc fr~min[ il~pectiOIL ~[ job site Cutting or modification of th~ roof trusses shall <br />be clearly shown in ~he engineer's design calo'a:tlous and drawings. <br /> <br />"APPROVED" only when this sheet is attached to plans. <br /> <br />2-Story Review 3 <br /> <br /> <br />