My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BUILD - 1513841
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
98-XXXXX
>
BUILD - 1513841
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/12/2013 8:51:10 AM
Creation date
11/16/2004 12:31:46 PM
Metadata
Fields
Template:
Permits
Permit Address
19752 OLMSTEAD RD NE
Permit City
Aurora
Permit Number
555-98-05271
Parcel Number
041W19C 01500
Permit Type
BUILD
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
BUILDING PERMIT <br />DATE/TIME 07/30/98 16:14 <br />TYPE Resident, addition/alteration <br />OCCUPANCY R-3 <br />CONST ~PE V-N <br />UGB: SITE: FD <br /> <br />PERHIT NO <br />STATUS <br />ISSUED <br />TO EXPIRE <br />PAGE <br /> <br />98-05271 <br />ISSUED <br />07/20/1998 <br />01/26/1999 <br /> 2 <br /> <br />PLAN REVIEW COMMENTS AND CONDITIONS <br /> <br />REQUIRED SETBACKS: Front: 20 Left: 20 Right: 20 Rear: 20 Special: <br /> <br />1. CALL BEFORE YOU DIG .... IT'S THE LAW. <br /> A~ENTION: Oregon law requires you to follow rules adopted <br /> by the Oregon Utility Notification Center. Those rules are <br /> set forth in OAR 952-001-0010 through OAR 952-001-0090. You <br /> may obtain copies of the rules by calling the center. <br /> (Note: The telephone number for the Oregon Utility Notifica- <br /> tion Center is (502) 232-1987). <br />2. THIS PLAN REVIEW WAS COMPLETED BY J TRUSSELL ON 7-24-98. <br />3. Approval of submitted plans is not an approval of omissions <br /> or oversights by this office or of noncompliance with any <br /> applicable regulations of local government. <br />4. BP, ABP, This structure uses a combination of Brace Wall <br /> Panels (BP) and Alternate Braced Wall Panels (ABP) to meet <br /> the code requirements for lateral wall bracing. Insure that <br /> all BP's are located as indicated on the plans, <br />5, TRUSS DESIGN. Roof trusses are required to be be designed by <br /> an Oregon registered Engineer or Architect, For trusses <br /> manufactured by an approved fabrication plant, have the <br /> design and layout drawings available at the construction <br /> site for the framing inspection, All jobsite cutting or <br /> modifications of the roof trusses shall be clearly shown in <br /> the engineer's design calculations and drawings. <br />6, EVERY SLEEPING ROOM shall have at least one openable window <br /> or exterior door approved for emergency egress or rescue, <br /> The window sill height shall not be more than 44 inches <br /> above the floor. The minimum net clear opening is 5.7 square <br /> feet. The minimum net clear opening height shall be 22 <br /> inches. The minimum net clear opening width shall be 20 <br /> inches. Exception: Grade floor windows may have a minimum <br /> net clear opening of 5 square feet, [Sec, 310,2, 210.2.1] <br />7, SMOKE DETECTORS / ALTERATIONS, When alterations, repairs or <br /> additions requiring a permit occur, or when sleeping rooms <br /> are added or created, the entire building shall be provided <br /> with smoke detectors located as required for new dwellings; <br /> the smoke detectors shall be interconnected and hard wired. <br /> EXCEPTION: Detectors shall not be required to be inter- <br /> connected and hard wired where the alterations~ repairs, or <br /> additions do not result in the exposure of electrical wiring <br /> by the removal of interior wall and ceiling finishes. <br /> [Sec. 316~i.1] <br />8. SMOKE DETECTORS shall be installed in each sleeping room, <br /> outside of each separate sleeping area in the immediate <br /> vicinity of the bedrooms and on each additional story of the <br /> dwelling including basements, All detectors located outside <br /> sleeping rooms shall be interconnected such that the <br /> actuation of one alarm will actuate these alarms in the <br /> individual unit and shall provide an alarm which will be <br /> audible in all sleeping areas. Smoke detectors shall be <br /> 110 volt with batter back-up. [Sec. 316.1] <br /> SMOKE DETECTOR / POWER. In new construction, the required <br /> smoke detectors shall receive their primary power from the <br /> building wiring when such wiring is served from a commercial <br /> source, and when primary power is interrupted, shall receive <br /> power from a battery, Wiring shall be permanent and not <br /> switched, Smoke detectors shall be permitted to be battery <br /> operated when installed in existing buildings without <br /> commercial power or in buildings which undergo alterations. <br /> repairs or additions regulated by Section 216.11 <br /> [Sec, 216.2] <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.