DATE/TIME <br />TYPE <br />OCCUPANCY <br />CONSTTYPE <br />UGB: SITE: <br /> <br />BUILDING PERMIT <br /> <br />06/30/98 08:37 PERMIT NO <br />New Commercial STATUS <br />S-5 ISSUED <br />II-N TO EXPIRE <br /> PAGE <br /> <br />98-05168 <br />ISSUED <br />06/30/1998 <br />12/27/1998 <br /> 2 <br /> <br />REQUIRED SETBACKS: <br /> <br /> Front: <br /> <br />1, <br /> <br /> PLAN REVIEW COMMENTS AND CONDITIONS <br /> <br /> Left: Right: Rear: <br /> OK AS PER SITE PLAN <br /> <br /> * THIS PLAN REVIEW WAS COMPLETED BY M. JONES ON 06/26/98. * <br /> <br /> * THE PLANS TO BE USED FOR HANGAR #17 ARE THE SAME * <br /> * AS FOR HANGAR #t2 AND #13, THEREFORE, THE PLANS * <br /> * FOR PERMIT #98-02760 AND #98-02761 SHALL BE ON * <br /> * SITE AND TO BE USED FOR THIS PERMIT. #98-05168 * <br /> <br /> 2. Approval of submitted plans is not an approval of omissions <br /> or oversights by this office or of noncompliance with any <br /> applicable regulations of local government, <br /> 2. ALLOWABLE AREA. (OSSC Sec 504) <br /> Basic Allowable Area: 12,000 sq ft (S-5/II-N) <br /> Proposed: 3,600 sq ft <br /> Maximum Height: 55 ft *******~***~**~************* <br /> Proposed: 22 ft * THIS IS HANGAR #17 * <br /> Maximum Stories: 2 * OF THE FOUR * <br /> Proposed: 1 ***~-**************~-********** <br /> There are four proposed hangars in this area, which Hangars <br /> 12 & 13 are to be built first. The aggregate area for all <br /> four buildings equals 14.400 sq ft. There are 2-yards avail <br /> able, for a 100% increase, therefore, the total square foot- <br /> age of the four hangars are 14.400. less than 18,000 sq ft. <br /> 4. This project may be subject to the architectural standards <br /> of the Americans with Disabilities Act of 1990 (ADA). <br /> Issuance of a building permit does not certify compliance <br /> with this Federal Statute. Copies of the guidelines and <br /> information concerning the ADA may be obtained from the <br /> Architectural and Transportation Barriers Compliance Board. <br /> 1-202-653-7834 (Voce/TDD) or 1-800-USA-ABLE. Failure to <br /> comply with the ADA may result in Federal fines and <br /> penalties, <br /> 5. Local Fire Districts may have additional requirements that <br /> affect this project, You are advised to contact the Fire <br /> District before you proceed, <br /> 6. This is a Plan Review covering the construction of the <br /> above indicated new buildin§. Plans have been reviewed for <br /> compliance with the provisions of the Oregon State <br /> Structural Specialty Code ('94 UBC) 1996 Edition. <br /> *******~-********** HANGAR UNIT #17 ***********~************* <br /> 7. OCCUPANCY CLASSIFICATION. (OSSC Sec 311,1) <br /> This building is classified as a Group S. Division 5 <br /> Occupancy: Aircraft hangar where work is limited to exchange <br /> of parts and maintenance requiring no open flame or welding. <br /> 8. TYPE OF CONSTRUCTION. (OSSC Sec 602.1) <br /> This building has been determined to be of Type II-N <br /> construction. <br /> The structural elements, floor construction, wall and <br /> permanent partitions shall be of noncombustible materials. <br /> Materials of construction and fire-resisitve requirements <br /> shall be as specified in Section 601. <br /> construction will be required between the hangars. <br /> 9, SPECIFIC USE PROVISIONS. (OSSC Sec 211,2.2.1) <br /> In areas where aircraft are stored, floor surfaces shall be <br /> of noncombustible, nonabsorbent materials. <br /> Floor shall drain to an approved oil separator or trap <br /> discharging to sewers in accordance with the Plumbing Code, <br /> EXECPTION: Floors may be surfaced or waterproofed with <br /> asphaltic paving materials in areas where <br /> airplanes are stored or operated, <br />10. SPECIFIC HAZARDS. (OSSC Sec 211.8) <br /> Storage and use of flammable and combustible liquids shall <br /> <br />Special: <br /> <br /> <br />