Laserfiche WebLink
DATE/TIME <br />l~fPE <br />OCCUPANCY <br />CONST TYPE <br />UGB: SITE: <br /> <br />BUILDING PERMIT <br /> <br />06/30/98 08:29 PERMIT NO <br />New Commercial STATUS <br />S-5 ISSUED <br />II-N TO EXPIRE <br /> PAGE <br /> <br />98-05167 <br />ISSUED <br />06/30/1998 <br />12/27/1998 <br /> 2 <br /> <br />REQUIRED SETBACKS: <br /> <br /> PLAN REVIEW COMMENTS AND CONDITIONS <br /> <br />Front: Left: Right: Rear: <br />OK AS PER SITE PLAN <br /> <br />Special: <br /> <br />* THIS PLAN REVIEW WAS COMPLETED BY M. JONES ON 06/26/98, * <br /> <br />* THE PLANS TO BE USED FOR HANGAR #18 ARE THE SAME * <br />* AS FOR HANGAR #12 AND #13. THEREFORE. THE PLANS * <br />* FOR PERMIT #98-02760 AND #98-02761 SHALL BE ON * <br />* SITE AND TO BE USED FOR THIS PERMIT. #98-05167 * <br /> <br /> 2, Approval of submitted plans is not an approval of omissions <br /> or oversights by this office or of noncompliance with any <br /> applicable regulations of local government, <br /> 3, ALLOWABLE AREA, (OSSC Sec 504) <br /> Basic Allowable Area: 12.000 sq ft (S-5/II-N) <br /> Proposed: 2.600 sq ft <br /> Maximum Height: 55 ft **~************************** <br /> Proposed: 22 ft * THIS IS HANGAR #18 * <br /> Maximum Stories: 2 * OF THE FOUR * <br /> Proposed: I **************~************* <br /> There are four proposed hangars in this area, which Hangars <br /> 12 & t3 are to be built first. The aggregate area for all <br /> four buildings equals 14,408 sq ft. There are 2-yards avail <br /> able, for a 100% increase, therefore, the total square foot- <br /> age of the four hangars are 14.400, less than 18.000 sq ft. <br /> 4. This project may be subject to the architectural standards <br /> of the Americans with Disabilities Act of 1990 (ADA). <br /> Issuance of a building permit does not certify compliance <br /> with this Federal Statute, Copies of the guidelines and <br /> information concerning the ADA may be obtained from the <br /> Architectural and Transportation Barriers Compliance Board. <br /> 1-202-653-7824 (Voce/TDD) or 1-800-USA-ABLE, Failure to <br /> comply with the ADA may result in Federal fines and <br /> penalties. <br /> 5. Local Fire Districts may have additional requirements that <br /> affect this project. You are advised to contact the Fire <br /> District before you proceed, <br /> 6, This is a Plan Review covering the construction of the <br /> above indicated new building. Plans have been reviewed for <br /> compliance with the provisions of the Oregon State <br /> Structural Specialty Code ('94 UBC) 1996 Edition. <br /> ~**************** HANGAR UNIT #18 *****************~-******* <br /> 7. OCCUPANCY CLASSIFICATION. (OSSC Sec 311,1) <br /> This building is classified as a Group S, Division 5 <br /> Occupancy: Aircraft hangar where work is limited to exchange <br /> of parts and maintenance requiring no open flame or welding. <br /> 8. TYPE OF CONSTRUCTION. (OSSC Sec 603.1) <br /> This building has been determined to be of Type II-N <br /> construction. <br /> The structural elements, floor construction, wall and <br /> permanent partitions shall be of noncombustible materials. <br /> Materials of construction and fire-resisitve requirements <br /> shall be as specified in Section 601. <br /> construction will be required between the hangars. <br /> 9. SPECIFIC USE PROVISIONS. (OSSC Sec 311.2,3,1) <br /> In areas where aircraft are stored, floor surfaces shall be <br /> of noncombustible, nonabsorbent materials. <br /> Floor shall drain to an approved oil separator or trap <br /> discharging to sewers in accordance with the Plumbing Code, <br /> EXECPTION: Floors may be surfaced or waterproofed with <br /> asphaltic paving materials in areas where <br /> airplanes are stored or operated. <br />10, SPECIFIC HAZARDS. (OSSC Sec 311.8) <br /> Storage and use of flammable and combustible liquids shall <br /> <br /> <br />