Laserfiche WebLink
DATE/TIME <br />TYPE <br />OCCUPANCY <br />CONST TYPE <br />UGB: AM SITE: <br /> <br /> DWELLING PERMIT <br />06/16/98 11~07 PERMIT NO <br />New Single Family Dwelling STATUS <br />R-3 ISSUED <br />V-N TO EXPIRE <br /> PAGE <br /> <br />98-04280 <br />ISSUED <br />06/16/1998 <br />12/13/1998 <br />2 <br /> <br /> PLAN REVIEW COMMENTS AND CONDITIONS <br /> <br />REQUIRED SETBACKS: Front: 20 Left: 5 Right: 5 ~ Rear: 5 Special: <br /> <br /> 1. CALL BEFORE YOU DIG .... IT'S THE LAW, <br /> ATTENTION: Oregon law requires you to follow rules adopted <br /> by the Oregon Utility Notification Center. Those rules are <br /> set forth in OAR 952-001-0010 through OAR 952-001-0090. You <br /> may obtain copies of the rules by calling the center. <br /> (Note: The telephone number for the Oregon Utility Notifica- <br /> tion Center is (503) 222-1987). <br /> 2, THIS PLAN REVIEW was completed by Mike Mendenhall on 6-16-98 <br /> This plan was reviewed under the 1996 Edition of the State <br /> of Oregon One and Two Family Dwelling Specialty Code. <br />3, Approval of submitted plans is not an approval of omissions <br /> or oversights by this office or of noncompliance with any <br /> applicable regulations of local government. <br />4. BP, ABP, PF, This structure uses a combination of Brace <br /> Wall Panels (BP). Alternate Braced Wall Panels (ABP), and a <br /> Portal Frame to meet the code requirements for lateral wall <br /> bracing, Insure that all BP;s and ABP's and Portal Frames <br /> are located as indicated on the plans and constructed as <br /> shown. <br /> 5, STANDARD TRUSSESS All job site cutting or modification of <br /> the roof trusses shall be clearly shown in the engineer's <br /> design calculations and drawings. Check for lateral bracing <br /> on truss T-3 and uplift restraints on trusses S-4A as <br /> required by truss engineering design. <br /> 6, LANDINGS. A minimum 2 foot x 3 foot landing shall be <br /> required on each side of an egress door. The floor or <br /> landing shall not be more than I and 1/2 inches lower than <br /> the top of the threshold. Exceptions: (1) At the top of a <br /> flight of stairs, provided the door does not swing over the <br /> stairs. (2) The landing at the exterior doorway shall not <br /> be more than 8 1/4 inches below the top of the threshold. <br /> [Sec, 312.1] <br />7, SMOKE DETECTOR / POWER. In new construction, the required <br /> smoke detectors shall receive their primary power from the <br /> building wiring when such wiring is served from a commercial <br /> source, and when primary power is interrupted, shall receive <br /> power from a battery. Wiring shall be permanent and not <br /> switched. Smoke detectors shall be permitted to be battery <br /> operated when installed in existing buildings without <br /> commercial power or in buildings which undergo alterations. <br /> repairs or additions regulated by Section 316.11 <br /> [Sec. 316.2] <br />8. INSTALLATION OF HEATING and cooling appliances shall conform <br /> to the conditions of their listing and label and the manu- <br /> facturer's installation instructions, The manufacturer's <br /> operating instructions shall remain attached to the <br /> appliance. Have the installation instructions available for <br /> the Building Inspector at the time of inspection. <br /> [Section 1305.1] <br />9. APPLIANCES THAT GENEP~qTE a glow, spark or flame capable of <br /> igniting gasoline vapors and located in a garage shall be <br /> installed with burners, burner ignition devices or heating <br /> elements and switches at least 18 inches above the floor <br /> level [Sec. 1307.3] <br />10. COMBUSTION AIR. Fuel burning equipment shall be provided <br /> with a sufficient supply of air for fuel combustion, draft <br /> hood dilution and ventilation of the space in which the <br /> equipment is installed. Plans do not show how combustion <br /> air is going to be provided. See the manufacturer's <br /> installation instructions and Chapter 20 of the State of <br /> Oregon One and Two Family Dwelling Specialty Code for <br /> guidance, [Sec, 2001.1] <br />11. EXTERIOR JOINTS around windows and door frames, between wall <br /> <br /> <br />