Laserfiche WebLink
SEPTIC PERMIT <br /> <br />DATE/TIME : 06/08/98 1t:14 PERMIT NO <br />TYPE : SP STATUS <br /> ISSUED <br /> TO EXPIRE <br /> PAGE <br /> <br />98-04273 <br />ISSUED <br />06/08/1998 <br />06/08/1999 <br />2 <br /> <br /> SEPTIC PERMIT <br /> <br />This property was previously evaluated 06/08/1998 for the feasibility to install a <br />septic system for a RESIDENTI~ building site, Based on the results of this stucLv, site <br />approval was granted. The approval is site specific to the area tested, and the septic <br />system must be located in the immediate area of the test pits. unless otherwise authorized <br />by this office. A new site evaluation may be required if the system is proposed for a <br />different area on the property. <br />This approval was given on the basis that the lot or parcel will not be further partitioned <br />or subdivided and that conditions on this property and on adjacent properties are not altered <br />in any manner which would prohibit the issuance of a permit, Soils in the approved area <br />shall not be altered by cutting, filling, or other developmental activities which would <br />impede the successful operation of the initial or replacement absorption systems, Failure <br />to comply with the above items may void this approval. <br />The site evaluation approval runs with the land. but the permit is non-transferable and non- <br />refundable. <br />Keep this document with your records. Show this permit to the septic installer prior to <br />installation of the system. Any deviation from the approved plan must have prior approval from <br />this office. <br />The following construction specifications shall apply to the installation of the initial <br /> septic system: <br /> <br /> TYPE OF INITIAL SYSTEM: STANDARD <br /> <br /> MINIMUM SEPTIC TANK CAPACITY: 1000 GALLONS <br /> LINEAL FEET OF DP~qINFIELD: 450 <br /> TYPE OF DISTRIBUTION: SERIAL <br /> DISPOSAL TRENCH DEPTH: 24INCHES, MINIMUM: 24INCHES. MAXIMUM <br /> TOTAL DRAIN MEDIA DEPTH: 12INCHES <br /> DRAIN MEDIA UNDER PIPE: 6INCHES <br /> MINIMUM SOIL BACKFILL: 12INCHES <br /> GROUND WATER INTERCEPTOR: Y <br /> <br /> The disposal trenches are constructed two (2) feet wide and on minimum ten (10) foot centers <br /> and with no line exceeding 125 feet in length. The trenches and perforated pipe are <br /> installed level (+/- one inch) and contoured to follow the natural ground surface, <br /> <br />TYPE OF FUTURE REPLACEMENT SYSTEM: STANDARD <br /> <br />COMMENTS AND CONDITIONS <br /> <br />1. THIS SEPTIC REVIEW WAS COMPLETED BY Z.EWING ON FEBRUARY 9, <br /> 1998, THE APPROVED AREA WHICH WAS PARTIALLY ELIMINATED HAS <br /> BEEN EXPANDED TO THE NORTH EAST WITH THE PLACEMENT OF <br /> ADDITIONAL TEST PITS. THE SITE IS APPROVED WITH THE IN- <br /> STALLATION OF A UPSLDPE CURTAIN DRAIN. ZE. <br />2. THE A1-FACHED OPJ~NGE CARD MUST BE POSTED AT THE COUNTY ROAD <br /> prior to requesting an inspection. The card must be located <br /> near the driveway to the property to assist the inspector in <br /> locating the access onto the site. <br />3. THE APPROVED SEPTIC SYSTEM AREA MUST BE PROTECTED from any <br /> vehicular traffic, livestock and farming activities. Other <br /> activities such as logging, excavating or filling, driveway <br /> placement or any similar activities may also damage the soil <br /> in the area and adversely affect the septic system approval. <br /> The areas of the initial septic system and the future repair <br /> system must both be protected. <br /> <br /> <br />