Laserfiche WebLink
DATE/TIME <br />TYPE <br />OCCUPANCY <br />CONST TYPE <br />UGB: DT SITE: <br /> <br /> BUILDING PERMIT <br />06/04/98 12:42 PERMIT NO <br />Resident. addition/alteration STATUS <br />R-2 ISSUED <br />V-N TO EXPIRE <br /> PAGE <br /> <br />98-03667 <br />ISSUED <br />06/04/1998 <br />12/01/1998 <br /> 2 <br /> <br />PLAN REVIEW COMMENTS AND CONDITIONS <br /> <br />REQUIRED SETBACKS: Front: 1 Left: 5 Right: 5 Rear: 15 Special: <br /> <br />1, THIS PLAN REVIEW WAS COMPLETED BY S, FREILINGER ON 6/2/98. <br />2, Approval of submitted plans is not an approval of omissions <br /> or oversights by this office or of noncompliance with any <br /> applicable regulations of local government, <br />3. INSTALL THE R-15 RIGID INSULATION AT THE PERIMETER OF THE SL <br /> AB AS SHOWN ON THE A~ACHED DETAIL NOT UNDER THE SLAB AS NOT <br /> ED ON THE PLANS. <br />4. FINISHED GRADE. Footings shall extend not less than 12 <br /> inches below the finish natural grade. Foundation walls <br /> shall extend at least 6 inches above the finished grade <br /> adjacent to the foundation at all points, except 4 inches is <br /> allowed where masonry veneer is used. [Fig. 402.1a. <br /> Section 404.1.3] <br />5. REPLACE ALL DRYROT DAMAGE AND REPLACE WITH ALL NEW MATERIALS <br /> WHICH AE FULL LENGTH REPLACEMENTS NOT PARTIAL STUDS, <br />6. THERE IS NOT ENOUGH INFORMATION SHOWN ON THE PLANS TO DETERM <br /> INE IF THE 4X6 HEADER AT THE PATIO DOOR IS ADEQUATE, IF THE <br /> WALL IS NONBEARING (GABLE END WALL) THEN THE 4×6 HEADER IS <br /> ADEQUATE, IF THE WALL IS BEARING. THE 4X6 HEADER IS NOT ADEQ <br /> UATE. A MINIMUM 4X8 IS REQUIRED IF THE PARALLEL WALL OF THE <br /> HOME IS 11'-6" AWAY. IF THE OPPOSITE BEARING WALL IS OVER <br /> i1'-6" AWAY, THE HEADER WILL HAVE TO BE RESIZED FOR THE LOAD <br /> <br /> <br />